Evidence map›Paper›PMID 36681748›Full record

ArticleAnnals of biomedical engineering2023

Thermal and Postural Effects on Fluid Mixing and Irrigation Patterns for Intraventricular Hemorrhage Treatment.

Coskun Bilgi, Faisal Amlani, Heng Wei, Nick Rizzi, Niema M Pahlevan

Open access · hybridAbstract read
In one paragraph

Article in Annals of biomedical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 3 countries.

Coskun BilgiDepartment of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA, USA.
Faisal AmlaniCentraleSupélec, ENS Paris-Saclay, CNRS, LMPS - Laboratoire de Mécanique Paris-Saclay, Université Paris-Saclay, 91190, Gif-Sur-Yvette, France.
Heng WeiDepartment of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA, USA.
Nick RizziResearch and Development Department, IRRAS Inc., San Diego, CA, USA.
Niema M PahlevanDepartment of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, CA, USA. pahlevan@usc.edu.ORCID http://orcid.org/0000-0001-7498-0396
University of Southern California · USCentre National de la Recherche Scientifique · FRInteractive Research and Development · PK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intraventricular hemorrhage is characterized by blood leaking into the cerebral ventricles and mixing with cerebrospinal fluid. A standard treatment method involves inserting a passive drainage catheter, known as an external ventricular drain (EVD), into the ventricle. EVDs have common adverse complications, including the occlusion of the catheter, that may lead to permanent neural damage or even mortality. In order to prevent such complications, a novel dual-lumen catheter (IRRAflow®) utilizing an active fluid exchange mechanism has been recently developed. However, the fluid dynamics of the exchange system have not been investigated. In this study, convective flow in a three-dimensional cerebral lateral ventricle with an inserted catheter is evaluated using an in-house lattice-Boltzmann-based fluid-solid interaction solver. Different treatment conditions are simulated, including injection temperature and patient position. Thermal and gravitational effects on medication distribution are studied using a dye simulator based on a recently-introduced (pseudo)spectral convection-diffusion equation solver. The effects of injection temperature and patient position on catheter performance are presented and discussed in terms of hematoma irrigation, vortical structures, mixing, and medication volume distribution. Results suggest that cold-temperature injections can increase catheter efficacy in terms of dye distribution and irrigation potential, both of which can be further guided by patient positioning.

Indexed as

Cerebral HemorrhageDrainageCathetersCerebral VentriclesHumansComputational fluid dynamics (CFD)Flow in lateral ventricleSelf-irrigating catheterTargeted deliveryThermally-induced convectionVentricular drain

Identifiers

PMID36681748
PMCPMC10172237
OpenAlexW4317676890

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked