Evidence map›Paper›PMID 36681083›Full record

ArticleMedical physics2023

Technical note: Extended longitudinal and lateral 3D imaging with a continuous dual-isocenter CBCT scan.

Tess Reynolds, Sepideh Hatamikia, Yiqun Q Ma, Owen Dillon, Grace Gang, J Webster Stayman, Ricky O'Brien

Abstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tess ReynoldsFaculty of Medicine and Health, University of Sydney, Sydney, Australia.
Sepideh HatamikiaAustrian Center for Medical Innovation and Technology, Wiener Neustadt, Austria.
Yiqun Q MaJohns Hopkins University, Baltimore, USA.
Owen DillonFaculty of Medicine and Health, University of Sydney, Sydney, Australia.
Grace GangJohns Hopkins University, Baltimore, USA.
J Webster StaymanJohns Hopkins University, Baltimore, USA.
Ricky O'BrienSchool of Health and Biomedical Sciences, RMIT University, Melbourne, Australia.

Funding

Task-Driven 3D Interventional ImagingR01EB027127 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI STAYMAN, JOSEPH WEBSTER · 2019 to 2022
$1.8M
NIBIB NIH HHS R01 EB027127NIH HHS R01EB027127Siemens Healthineers
6 · The paper itself

Abstract

backgroundThe clinical benefits of intraoperative cone beam CT (CBCT) during orthopedic procedures include (1) improved accuracy for procedures involving the placement of hardware and (2) providing immediate surgical verification. PURPOSE: Orthopedic interventions often involve long and wide anatomical sites (e.g., lower extremities). Therefore, in order to ensure that the clinical benefits are available to all orthopedic procedures, we investigate the feasibility of a novel imaging trajectory to simultaneously expand the CBCT field-of-view longitudinally and laterally.

methodsA continuous dual-isocenter imaging trajectory was implemented on a clinical robotic CBCT system using additional real-time control hardware. The trajectory consisted of 200° circular arcs separated by alternating lateral and longitudinal table translations. Due to hardware constraints, the direction of rotation (clockwise/anticlockwise) and lateral table translation (left/right) was reversed every 400°. X-ray projections were continuously acquired at 15 frames/s throughout all movements. A whole-body phantom was used to verify the trajectory. As comparator, a series of conventional large volume acquisitions were stitched together. Image quality was quantified using Root Mean Square Deviation (RMSD), Mean Absolute Percentage Deviation (MAPD), Structural Similarity Index Metric (SSIM) and Contrast-to-Noise Ratio (CNR).

resultsThe imaging volume produced by the continuous dual-isocenter trajectory had dimensions of L = 95 cm × W = 45 cm × H = 45 cm. This enabled the hips to the feet of the whole-body phantom to be captured in approximately half the imaging dose and acquisition time of the 11 stitched conventional acquisitions required to match the longitudinal and lateral imaging dimensions. Compared to the stitched conventional images, the continuous dual-isocenter acquisition had RMSD of 4.84, MAPD of 6.58% and SSIM of 0.99. The CNR of the continuous dual-isocenter and stitched conventional acquisitions were 1.998 and 1.999, respectively.

conclusionExtended longitudinal and lateral intraoperative volumetric imaging is feasible on clinical robotic CBCT systems.

Indexed as

Imaging, Three-DimensionalSpiral Cone-Beam Computed TomographyCone-Beam Computed TomographyPhantoms, ImagingRadionuclide Imagingcone beam CTimage reconstructionorthopaedics

Identifiers

PMID36681083
PMCPMC13123423

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.