Evidence map›Paper›PMID 36679629›Full record

ArticleSensors (Basel, Switzerland)2023

Neural Network-Based Active Load-Sensing Scheme and Stiffness Adjustment for Pneumatic Soft Actuators for Minimally Invasive Surgery Support.

Yuxi Lu, Zhongchao Zhou, Shota Kokubu, Ruian Qin, Pablo E Tortós Vinocour, Wenwei Yu

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Yuxi LuDepartment of Medical Engineering, Graduate School of Engineering, Chiba University, Chiba 263-8522, Japan.ORCID 0000-0003-1205-3524
Zhongchao ZhouDepartment of Medical Engineering, Graduate School of Engineering, Chiba University, Chiba 263-8522, Japan.ORCID 0000-0002-8799-7362
Shota KokubuDepartment of Medical Engineering, Graduate School of Engineering, Chiba University, Chiba 263-8522, Japan.ORCID 0000-0003-1083-1628
Ruian QinDepartment of Medical Engineering, Graduate School of Engineering, Chiba University, Chiba 263-8522, Japan.
Pablo E Tortós VinocourDepartment of Medical Engineering, Graduate School of Engineering, Chiba University, Chiba 263-8522, Japan.
Wenwei YuDepartment of Medical Engineering, Graduate School of Engineering, Chiba University, Chiba 263-8522, Japan.
Chiba University · JP

Funding

Japan Science and Technology Agency JPMJFS2107
6 · The paper itself

Abstract

To provide a stable surgical view in Minimally Invasive Surgery (MIS), it is necessary for a flexible endoscope applied in MIS to have adjustable stiffness to resist different external loads from surrounding organs and tissues. Pneumatic soft actuators are expected to fulfill this role, since they could feed the endoscope with an internal access channel and adjust their stiffness via an antagonistic mechanism. For that purpose, it is essential to estimate the external load. In this study, we proposed a neural network (NN)-based active load-sensing scheme and stiffness adjustment for a soft actuator for MIS support with antagonistic chambers for three degrees of freedom (DoFs) of control. To deal with the influence of the nonlinearity of the soft actuating system and uncertainty of the interaction between the soft actuator and its environment, an environment exploration strategy was studied for improving the robustness of sensing. Moreover, a NN-based inverse dynamics model for controlling the stiffness of the soft actuator with different flexible endoscopes was proposed too. The results showed that the exploration strategy with different sequence lengths improved the estimation accuracy of external loads in different conditions. The proposed method for external load exploration and inverse dynamics model could be used for in-depth studies of stiffness control of soft actuators for MIS support.

Indexed as

RoboticsEndoscopesEquipment DesignMinimally Invasive Surgical ProceduresNeural Networks, Computeradjust stiffnessexploration strategyNN-based active load-sensing schemesoft actuator in MIS

Identifiers

PMID36679629
PMCPMC9861017
OpenAlexW4315647740

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.