Evidence map›Paper›PMID 36678573›Full record

ArticlePharmaceuticals (Basel, Switzerland)2023

Development and Validation of a Non-Targeted Screening Method for Most Psychoactive, Analgesic, Anaesthetic, Anti-Diabetic, Anti-Coagulant and Anti-Hypertensive Drugs in Human Whole Blood and Plasma Using High-Resolution Mass Spectrometry.

Catherine Feliu, Celine Konecki, Yoann Cazaubon, Laurent Binet, Damien Vautier, Aurélie Fouley, Claire Gozalo, Zoubir Djerada

Open access · goldAbstract read
In one paragraph

Article in Pharmaceuticals (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
1.1field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 5 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Catherine FeliuDepartment of Pharmacology, EA 3801, SFR CAP-Santé, Reims University Hospital, 51 Rue Cognacq-Jay, CEDEX, 51095 Reims, France.ORCID 0000-0002-3928-8908
Celine KoneckiDepartment of Pharmacology, EA 3801, SFR CAP-Santé, Reims University Hospital, 51 Rue Cognacq-Jay, CEDEX, 51095 Reims, France.ORCID 0000-0002-6214-1613
Yoann CazaubonInstitute Desbrest of Epidemiology and Public Health, INSERM, Montpellier University, Department of Pharmacology, Montpellier University Hospital, Avenue du Doyen Gaston Giraud, 34090 Montpellier, France.ORCID 0000-0003-1032-0879
Laurent BinetDepartment of Pharmacology, EA 3801, SFR CAP-Santé, Reims University Hospital, 51 Rue Cognacq-Jay, CEDEX, 51095 Reims, France.
Damien VautierDepartment of Pharmacology, EA 3801, SFR CAP-Santé, Reims University Hospital, 51 Rue Cognacq-Jay, CEDEX, 51095 Reims, France.
Aurélie FouleyDepartment of Pharmacology, EA 3801, SFR CAP-Santé, Reims University Hospital, 51 Rue Cognacq-Jay, CEDEX, 51095 Reims, France.
Claire GozaloDepartment of Pharmacology, EA 3801, SFR CAP-Santé, Reims University Hospital, 51 Rue Cognacq-Jay, CEDEX, 51095 Reims, France.
Zoubir DjeradaDepartment of Pharmacology, EA 3801, SFR CAP-Santé, Reims University Hospital, 51 Rue Cognacq-Jay, CEDEX, 51095 Reims, France.ORCID 0000-0002-4022-7889
Centre Hospitalier Universitaire de Reims · FRInserm · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: In toxicological laboratories, various screening methods can be used to identify compounds involved in intoxication. High-resolution mass spectrometry has been increasingly used in this context for the last years, because of its sensitivity and reliability. Here, we present the development and validation of a screening method that uses liquid chromatography coupled with a high-resolution mass spectrometer. (2) Methods: This method required only 100 µL of whole blood or plasma sample. Pretreatment consisted of a rapid and simple deproteinisation with methanol/acetonitrile and zinc sulphate. This new assay was validated according to international guidelines. (3) Results: To perform the method validation, 53 compounds were selected. The selection criteria were as follows: various chemical structures and therapeutic families (>15), large m/z distribution, positive or negative ionisation mode, and various elution times. The assays showed high selectivity and specificity, with optimal process efficiency. The identification limits, determined using predefined criteria, were established at sub-therapeutic or therapeutic concentrations. Applicability was evaluated using spiked plasma controls and external quality controls. (4) Conclusions: The new method was then successfully applied to routine clinical and forensic samples.

Indexed as

drug screeninghigh-resolution mass spectrometryOrbitrapplasmapoisoningwhole blood

Identifiers

PMID36678573
PMCPMC9865759
OpenAlexW4313466282

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.