Evidence map›Paper›PMID 36676560›Full record

ArticleMaterials (Basel, Switzerland)2023

A Highly Versatile X-ray and Electron Beam Diamond Dosimeter for Radiation Therapy and Protection.

Sara Pettinato, Marco Girolami, Antonella Stravato, Valerio Serpente, Daniela Musio, Maria C Rossi, Daniele M Trucchi, Riccardo Olivieri, Stefano Salvatori

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Sara PettinatoEngineering Faculty, Niccolò Cusano University, Via Don Carlo Gnocchi 3, 00166 Rome, Italy.
Marco GirolamiIstituto di Struttura della Materia, Consiglio Nazionale delle Ricerche (ISM-CNR), DiaTHEMA Lab, Strada Provinciale 35D, 9, Montelibretti, 00010 Rome, Italy.ORCID 0000-0003-0063-3636
Antonella StravatoAzienda Ospedaliera "San Giovanni-Addolorata", Via dell'Amba Aradam, 8, 00184 Rome, Italy.
Valerio SerpenteIstituto di Struttura della Materia, Consiglio Nazionale delle Ricerche (ISM-CNR), DiaTHEMA Lab, Strada Provinciale 35D, 9, Montelibretti, 00010 Rome, Italy.ORCID 0000-0002-4137-1831
Daniela MusioAzienda Ospedaliera "San Giovanni-Addolorata", Via dell'Amba Aradam, 8, 00184 Rome, Italy.
Maria C RossiDepartment of Industrial, Electronic and Mechanical Engineering, Università degli Studi Roma Tre, Via Vito Volterra 62, 00146 Rome, Italy.
Daniele M TrucchiIstituto di Struttura della Materia, Consiglio Nazionale delle Ricerche (ISM-CNR), DiaTHEMA Lab, Strada Provinciale 35D, 9, Montelibretti, 00010 Rome, Italy.ORCID 0000-0001-8278-4707
Riccardo OlivieriAzienda Ospedaliera "San Giovanni-Addolorata", Via dell'Amba Aradam, 8, 00184 Rome, Italy.
Stefano SalvatoriEngineering Faculty, Niccolò Cusano University, Via Don Carlo Gnocchi 3, 00166 Rome, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Radiotherapy is now recognized as a pillar in the fight against cancer. Two different types are currently used in clinical practice: (1) external beam radiotherapy, using high-energy X-rays or electron beams, both in the MeV-range, and (2) intraoperative radiotherapy, using low-energy X-rays (up to 50 keV) and MeV-range electron beams. Versatile detectors able to measure the radiation dose independently from the radiation nature and energy are therefore extremely appealing to medical physicists. In this work, a dosimeter based on a high-quality single-crystal synthetic diamond sample was designed, fabricated and characterized under low-energy X-rays, as well as under high-energy pulsed X-rays and electron beams, demonstrating excellent linearity with radiation dose and dose-rate. Detector sensitivity was measured to be 0.299 ± 0.002 µC/Gy under 6 MeV X-ray photons, and 0.298 ± 0.004 µC/Gy under 6 MeV electrons, highlighting that the response of the diamond dosimeter is independent of the radiation nature. Moreover, in the case of low-energy X-rays, an extremely low limit of detection (23 nGy/s) was evaluated, pointing out the suitability of the device to radiation protection dosimetry.

Indexed as

CVD diamond detectorsdosimetryelectron beamsradiation protectionradiation therapyX-rays

Identifiers

PMID36676560
PMCPMC9861322

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.