Evidence map›Paper›PMID 36676374›Full record

ArticleMaterials (Basel, Switzerland)2023

Electrochemical, Biological, and Technological Properties of Anodized Titanium for Color Coded Implants.

Josef Hlinka, Kamila Dostalova, Kristina Cabanova, Roman Madeja, Karel Frydrysek, Jan Koutecky, Zuzana Rybkova, Katerina Malachova, Osamu Umezawa

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.1field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 10 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 2 countries.

Josef HlinkaFaculty of Materials and Technology, Department of Materials Engineering, VSB-Technical University of Ostrava, 17. Listopadu 2172/15, 708 00 Ostrava, Czech Republic.ORCID 0000-0001-9347-670X
Kamila DostalovaCentre for Advanced Innovation Technologies, VSB-Technical University of Ostrava, 17. Listopadu 2172/15, 708 00 Ostrava, Czech Republic.
Kristina CabanovaCentre for Advanced Innovation Technologies, VSB-Technical University of Ostrava, 17. Listopadu 2172/15, 708 00 Ostrava, Czech Republic.ORCID 0000-0002-1622-8961
Roman MadejaTrauma Center, University Hospital Ostrava, 17. Listopadu 1790, 708 52 Ostrava, Czech Republic.
Karel FrydrysekInstitute of Emergency Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic.ORCID 0000-0003-2714-2802
Jan KouteckyMedin a.s., Vlachovicka 619, 592 31 Nove Mesto na Morave, Czech Republic.
Zuzana RybkovaInstitute of Emergency Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic.ORCID 0000-0001-8803-5336
Katerina MalachovaInstitute of Emergency Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic.ORCID 0000-0001-9997-4881
Osamu UmezawaFaculty of Engineering, Yokohama National University, 79-5 Tokiwadai, Hodogoaya, Yokohama 240-8501, Japan.ORCID 0000-0003-0380-1885
University of Ostrava · CZVSB - Technical University of Ostrava · CZMedin (Czechia) · CZUniversity Hospital Ostrava · CZYokohama National University · JP

Funding

European Union CZ.02.1.01/0.0/0.0/17_049/0008441
6 · The paper itself

Abstract

Anodization coloring of titanium tools or implants is one of the common methods for the differentiation of each application by its size or type. Commercial purity titanium grade 4 plates (50 × 20 × 0.1 mm) were tested to obtain their electrochemical and other technological properties. The coloring process was done using the potential of 15, 30, 45, 60, and 75 Volts for 5 s in 1 wt. % citric acid in demineralized water solution. Organic acids solutions generally produce better surface quality compared to inorganic acids. The contact angle of colored surfaces was measured by the sessile drop method. Electrochemical impedance spectroscopy and potentiodynamic polarization were used for the determination of selected electrochemical and corrosion parameters of the tested surfaces. It was found that the anodization process decreases corrosion potential significantly. It was also confirmed that a higher potential used for anodization results in higher polarization resistance but also a decrease in corrosion potential. The anodization process at 75 V produces surfaces with the lowest corrosion rate under 1 nm/year and the noblest corrosion potential. It was confirmed that the anodization process in citric acid does not affect titanium cytotoxicity.

Indexed as

anodizationbiocompatibilitycorrosion propertiespolarizationtitanium

Identifiers

PMID36676374
PMCPMC9866561
OpenAlexW4313889567

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.