Evidence map›Paper›PMID 36675786›Full record

ReviewJournal of personalized medicine2023

Three-Dimensional Accuracy and Stability of Personalized Implants in Orthognathic Surgery: A Systematic Review and a Meta-Analysis.

Alexandru Diaconu, Michael Boelstoft Holte, Gabriele Berg-Beckhoff, Else Marie Pinholt

Abstract readReview
In one paragraph

Review in Journal of personalized medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 4 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Alexandru Diaconu3D Lab Denmark, Department of Oral and Maxillofacial Surgery, University Hospital of Southern Denmark, Finsensgade 35, 6700 Esbjerg, Denmark.
Michael Boelstoft Holte3D Lab Denmark, Department of Oral and Maxillofacial Surgery, University Hospital of Southern Denmark, Finsensgade 35, 6700 Esbjerg, Denmark.ORCID 0000-0002-0538-2779
Gabriele Berg-BeckhoffDepartment of Public Health, Faculty of Health Sciences, University of Southern Denmark, Degnevej 14, 6705 Esbjerg, Denmark.ORCID 0000-0003-1614-938X
Else Marie Pinholt3D Lab Denmark, Department of Oral and Maxillofacial Surgery, University Hospital of Southern Denmark, Finsensgade 35, 6700 Esbjerg, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This systematic review aimed to determine the accuracy/stability of patient-specific osteosynthesis (PSI) in orthognathic surgery according to three-dimensional (3D) outcome analysis and in comparison to conventional osteosynthesis and computer-aided designed and manufactured (CAD/CAM) splints or wafers. The PRISMA guidelines were followed and six academic databases and Google Scholar were searched. Records reporting 3D accuracy/stability measurements of bony segments fixated with PSI were included. Of 485 initial records, 21 met the eligibility (566 subjects), nine of which also qualified for a meta-analysis (164 subjects). Six studies had a high risk of bias (29%), and the rest were of low or moderate risk. Procedures comprised either single-piece or segmental Le Fort I and/or mandibular osteotomy and/or genioplasty. A stratified meta-analysis including 115 subjects with single-piece Le Fort I PSI showed that the largest absolute mean deviations were 0.5 mm antero-posteriorly and 0.65° in pitch. PSIs were up to 0.85 mm and 2.35° more accurate than conventional osteosynthesis with CAD/CAM splint or wafer (p < 0.0001). However, the clinical relevance of the improved accuracy has not been shown. The literature on PSI for multi-piece Le Fort I, mandibular osteotomies and genioplasty procedure is characterized by high methodological heterogeneity and a lack of randomized controlled trials. The literature is lacking on the 3D stability of bony segments fixated with PSI.

Indexed as

accuracymeta-analysisorthognathic surgerypatient-specific implantsstabilitysystematic reviewthree-dimensional

Identifiers

PMID36675786
PMCPMC9867342

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.