Evidence map›Paper›PMID 36673137›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Utilisation of 3D Printing in the Manufacturing of an Anthropomorphic Paediatric Head Phantom for the Optimisation of Scanning Parameters in CT.

Merim Jusufbegović, Adi Pandžić, Mustafa Busuladžić, Lejla M Čiva, Azra Gazibegović-Busuladžić, Adnan Šehić, Sandra Vegar-Zubović, Rahima Jašić, Adnan Beganović

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Merim JusufbegovićRadiology Clinic, Sarajevo University Clinical Center, 71000 Sarajevo, Bosnia and Herzegovina.ORCID 0000-0003-4371-0945
Adi PandžićDepartment of Mechanical Production Engineering, Faculty of Mechanical Engineering Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.ORCID 0000-0003-0807-5122
Mustafa BusuladžićFaculty of Medicine, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.ORCID 0000-0003-2610-2569
Lejla M ČivaSarajevo Medical School, University Sarajevo School of Science and Technology, 71210 Ilidža, Bosnia and Herzegovina.ORCID 0000-0002-5464-3322
Azra Gazibegović-BusuladžićFaculty of Science, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.ORCID 0000-0002-8498-542X
Adnan ŠehićDepartment of Radiological Technologies, Faculty of Health Studies, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.ORCID 0000-0003-2960-3801
Sandra Vegar-ZubovićRadiology Clinic, Sarajevo University Clinical Center, 71000 Sarajevo, Bosnia and Herzegovina.ORCID 0000-0002-6276-2348
Rahima JašićDepartment of Radiation Protection and Medical Physics, Sarajevo University Clinical Center, 71000 Sarajevo, Bosnia and Herzegovina.
Adnan BeganovićFaculty of Science, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.ORCID 0000-0003-4193-5390
University of Sarajevo · BASarajevo School of Science and Technology · BA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Computed tomography (CT) is a diagnostic imaging process that uses ionising radiation to obtain information about the interior anatomic structure of the human body. Considering that the medical use of ionising radiation implies exposing patients to radiation that may lead to unwanted stochastic effects and that those effects are less probable at lower doses, optimising imaging protocols is of great importance. In this paper, we used an assembled 3D-printed infant head phantom and matched its image quality parameters with those obtained for a commercially available adult head phantom using the imaging protocol dedicated for adult patients. In accordance with the results, an optimised scanning protocol was designed which resulted in dose reductions for paediatric patients while keeping image quality at an adequate level.

Indexed as

3D printingadditive manufacturingcomputed tomographyCTDIdoseimagingradiation

Identifiers

PMID36673137
PMCPMC9858362
OpenAlexW4316468142

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.