Evidence map›Paper›PMID 36673092›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Evaluation of Accuracy and Performance of a Novel, Fully Gantry Integrated 3D Laser System for Computed Tomography Guided Needle Placement: A Phantom Study.

Katharina Weigel, Rahel A Kubik-Huch, Matthias Baer-Beck, Christian Canstein, Michael Kostrzewa

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 3 countries.

Katharina WeigelDepartment of Radiology, Baden Cantonal Hospital, 5404 Baden, Switzerland.
Rahel A Kubik-HuchDepartment of Radiology, Baden Cantonal Hospital, 5404 Baden, Switzerland.ORCID 0000-0002-3636-8697
Matthias Baer-BeckSiemens Healthineers, 91301 Forchheim, Germany.
Christian CansteinSiemens Healthineers, 91301 Forchheim, Germany.
Michael KostrzewaDepartment of Radiology, Baden Cantonal Hospital, 5404 Baden, Switzerland.
Siemens Healthineers (Germany) · DEBarking, Havering And Redbridge University Hospitals NHS Trust · GBHeidelberg University · DEKantonsspital Baden · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this phantom study was to compare the accuracy, speed and technical performance of CT guided needle placement using a conventional technique versus a novel, gantry integrated laser guidance system for both an expert and a novice. A total of 80 needle placements were performed in an abdominal phantom using conventional CT guidance and a laser guidance system. Analysis of pooled results of expert and novice showed a significant reduction of time (277 vs. 204 s, p = 0.001) and of the number of needle corrections (3.28 vs. 1.58, p < 0.001) required when using laser guidance versus conventional technique. No significant improvement in absolute (3.81 vs. 3.41 mm, p = 0.213) or angular deviation (2.85 vs. 2.18°, p = 0.079) was found. With either approach, the expert was significantly faster (conventional guidance: 207 s vs. 346 s, p < 0.001; laser guidance: 144 s vs. 264 s, p < 0.001) and required fewer needle corrections (conventional guidance: 4 vs. 3, p = 0.027; laser guidance: 2 vs. 1, p = 0.001) than the novice. The laser guidance system helped both the expert and the novice to perform CT guided interventions in a phantom faster and with fewer needle corrections compared to the conventional technique, while achieving similar accuracy.

Indexed as

computed tomographyinterventionlaser-guidancephantomradiation exposuresafety

Identifiers

PMID36673092
PMCPMC9858339
OpenAlexW4315796071

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.