Evidence map›Paper›PMID 36673055›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Assessment of Calcium Score Cutoff Point for Clinically Significant Aortic Stenosis on Lung Cancer Screening Program Low-Dose Computed Tomography-A Cross-Sectional Analysis.

Kaja Klein-Awerjanow, Witold Rzyman, Robert Dziedzic, Jadwiga Fijalkowska, Piotr Spychalski, Edyta Szurowska, Marcin Fijalkowski

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Kaja Klein-AwerjanowSecond Department of Radiology, Medical University of Gdansk, 80-210 Gdansk, Poland.ORCID 0000-0001-5296-5371
Witold RzymanDepartment of Thoracic Surgery, Medical University of Gdansk, 80-210 Gdansk, Poland.
Robert DziedzicDepartment of Thoracic Surgery, Medical University of Gdansk, 80-210 Gdansk, Poland.
Jadwiga FijalkowskaSecond Department of Radiology, Medical University of Gdansk, 80-210 Gdansk, Poland.
Piotr SpychalskiDepartment of General, Endocrine and Transplant Surgery, Medical University of Gdansk, 80-210 Gdansk, Poland.ORCID 0000-0001-7111-4660
Edyta SzurowskaSecond Department of Radiology, Medical University of Gdansk, 80-210 Gdansk, Poland.ORCID 0000-0002-7042-4381
Marcin FijalkowskiFirst Department of Cardiology, Medical University of Gdansk, 80-210 Gdansk, Poland.ORCID 0000-0002-2913-5457
Gdańsk Medical University · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Low-dose computed tomography (LDCT) is predominantly applied in lung cancer screening programs. Tobacco smoking is the main risk factor for developing lung cancer but is also common for cardiovascular diseases, including aortic stenosis (AS). Consequently, an increased prevalence of cardiovascular diseases is expected in lung cancer screenees. Therefore, initial aortic valve calcification evaluation should be additionally performed on LDCT. The aim of this study was to estimate a calcium score (CS) cutoff point for clinically significant AS diagnosis based on LDCT, confirmed by echocardiographic examination. The study included 6631 heavy smokers who participated in a lung cancer screening program (MOLTEST BIS). LDCTs were performed on all individuals and were additionally assessed for aortic valve calcification with the use of CS according to the Agatston method. Patients with CS ≥ 900 were referred for echocardiography to confirm the diagnosis of AS and to evaluate its severity. Of 6631 individuals, 54 met the inclusion criteria and underwent echocardiography for confirmation and assessment of AS. Based on that data, receiver operating characteristic (ROC) curves of CS were plotted, and cutoff points for clinically significant AS diagnosis were established: A CS of 1758 for at least moderate AS had 85.71% (CI 65.36-95.02%) sensitivity and 75.76% (CI 58.98-87.17%) specificity; a CS of 2665 for severe AS had 87.5% (CI 73.89-94.54%) sensitivity and 76.92% (CI 49.74-91.82%) specificity. This is the first study to assess possible CS cutoff points for diagnosing clinically significant AS detected by LDCT in lung cancer screening participants. LDCT with CS assessment could enable early detection of patients with clinically significant AS and therefore identify patients who require appropriate treatment.

Indexed as

aortic valve calcificationaortic valve stenosisASLDCTlow-dose computed tomographylung cancer screeningscreening

Identifiers

PMID36673055
PMCPMC9858230
OpenAlexW4313889466

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.