Evidence map›Paper›PMID 36673000›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Proposing Intelligent Approach to Predicting Air Kerma within Radiation Beams of Medical X-ray Imaging Systems.

Yanjie Lu, Nan Zheng, Mingtao Ye, Yihao Zhu, Guodao Zhang, Ehsan Nazemi, Jie He

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yanjie LuDepartment of Digital Media Technology, Hangzhou Dianzi University, Hangzhou 310018, China.ORCID 0000-0001-7203-1445
Nan ZhengCollege of Pharmacy, Wenzhou Medical University, Wenzhou 325035, China.ORCID 0000-0003-3632-1888
Mingtao YeDepartment of Digital Media Technology, Hangzhou Dianzi University, Hangzhou 310018, China.
Yihao ZhuSchool of Economics and Management, Zhejiang Ocean University, Zhoushan 316022, China.
Guodao ZhangDepartment of Digital Media Technology, Hangzhou Dianzi University, Hangzhou 310018, China.ORCID 0000-0002-6264-5854
Ehsan NazemiDepartment of Physics, University of Antwerp, 2610 Antwerp, Belgium.ORCID 0000-0001-5457-6943
Jie HeThe First People's Hospital of Fuyang District, Hangzhou 310000, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The air kerma is a key parameter in medical diagnostic radiology. Radiologists use the air kerma parameter to evaluate organ doses and any associated patient hazards. The air kerma can be simply described as the deposited kinetic energy once a photon passes through the air, and it represents the intensity of the radiation beam. Due to the heel effect in the X-ray sources of medical imaging systems, the air kerma is not uniform within the X-ray beam's field of view. Additionally, the X-ray tube voltage can also affect this nonuniformity. In this investigation, an intelligent technique based on the radial basis function neural network (RBFNN) is presented to predict the air kerma at every point within the fields of view of the X-ray beams of medical diagnostic imaging systems based on discrete and limited measured data. First, a diagnostic imaging system was modeled with the help of the Monte Carlo N Particle X version (MCNPX) code. It should be noted that a tungsten target and beryllium window with a thickness of 1 mm (no extra filter was applied) were used for modeling the X-ray tube. Second, the air kerma was calculated at various discrete positions within the conical X-ray beam for tube voltages of 40 kV, 60 kV, 80 kV, 100 kV, 120 kV, and 140 kV (this range covers most medical X-ray imaging applications) to provide the adequate dataset for training the network. The X-ray tube voltage and location of each point at which the air kerma was calculated were used as the RBFNN inputs. The calculated air kerma was also assigned as the output. The trained RBFNN model was capable of estimating the air kerma at any random position within the X-ray beam's field of view for X-ray tube voltages within the range of medical diagnostic radiology (20-140 kV).

Indexed as

air kermamedical diagnostic radiologyradiologyRBF neural networkX-ray beam

Identifiers

PMID36673000
PMCPMC9858575

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.