Evidence map›Paper›PMID 36671912›Full record

ArticleBiosensors2023

Highly Sensitive Readout Interface for Real-Time Differential Precision Measurements with Impedance Biosensors.

Sara Neshani, Kasra Momeni, Degang J Chen, Nathan M Neihart

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Sara NeshaniElectrical and Computer Engineering Department, University of Alabama, Tuscaloosa, AL 35401, USA.
Kasra MomeniMechanical Engineering Department, University of Alabama, Tuscaloosa, AL 35401, USA.ORCID 0000-0002-4209-1129
Degang J ChenElectrical Engineering Department, Iowa State University, Ames, IA 50010, USA.
Nathan M NeihartElectrical Engineering Department, Iowa State University, Ames, IA 50010, USA.
Iowa State University · USUniversity of Alabama · US

Funding

United States Department of Agriculture 2015-67021-23128
6 · The paper itself

Abstract

Field deployment is critical to developing numerous sensitive impedance transducers. Precise, cost-effective, and real-time readout units are being sought to interface these sensitive impedance transducers for various clinical or environmental applications. This paper presents a general readout method with a detailed design procedure for interfacing impedance transducers that generate small fractional changes in the impedance characteristics after detection. The emphasis of the design is obtaining a target response resolution considering the accuracy in real-time. An entire readout unit with amplification/filtering and real-time data acquisition and processing using a single microcontroller is proposed. Most important design parameters, such as the signal-to-noise ratio (SNR), common-mode-to-differential conversion, digitization configuration/speed, and the data processing method are discussed here. The studied process can be used as a general guideline to design custom readout units to interface with various developed transducers in the laboratory and verify the performance for field deployment and commercialization. A single frequency readout unit with a target 8-bit resolution to interface differentially placed transducers (e.g., bridge configuration) is designed and implemented. A single MCU is programmed for real-time data acquisition and sine fitting. The 8-bit resolution is achieved even at low SNR levels of roughly 7 dB by setting the component values and fitting algorithm parameters with the given methods.

Indexed as

Biosensing TechniquesAlgorithmsElectric ImpedanceSignal-To-Noise Ratioimpedance biosensorinterfacelow-costprecisionreadoutreal-timesensitive

Identifiers

PMID36671912
PMCPMC9856043
OpenAlexW4313397796

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.