Multifrequency Microwave Radiometry for Characterizing the Internal Temperature of Biological Tissues.
Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
The analysis of near-field radiometry is described for characterizing the internal temperature of biological tissues, for which a system based on multifrequency pseudo-correlation-type radiometers is proposed. The approach consists of a new topology with multiple output devices that enables real-time calibration and performance assessment, recalibrating the receiver through simultaneous measurable outputs. Experimental characterization of the prototypes includes a well-defined calibration procedure, which is described and demonstrated, as well as DC conversion from the microwave input power. Regarding performance, high sensitivity is provided in all the bands with noise temperatures around 100 K, reducing the impact of the receiver on the measurements and improving its sensitivity. Calibrated temperature retrievals exhibit outstanding results for several noise sources, for which temperature deviations are lower than 0.1% with regard to the expected temperature. Furthermore, a temperature recovery test for biological tissues, such as a human forearm, provides temperature values on the order of 310 K. In summary, the radiometers design, calibration method and temperature retrieval demonstrated significant results in all bands, validating their use for biomedical applications.