Evidence map›Paper›PMID 36671586›Full record

ArticleBioengineering (Basel, Switzerland)2022

Micro-Slab Coil Design for Hyperpolarized Metabolic Flux Analysis in Multiple Samples.

Geonhui Lee, Thomas Ruan, Claudia Wong, Kofi Deh, Alli Abolarin, Alexander Correa, Kayvan R Keshari, Sangmoo Jeong

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Geonhui LeeDepartment of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
Thomas RuanDepartment of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA.
Claudia WongDepartment of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
Kofi DehDepartment of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA.
Alli AbolarinDepartment of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
Alexander CorreaDepartment of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
Kayvan R KeshariDepartment of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA.
Sangmoo JeongDepartment of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.ORCID 0000-0001-9428-6668
Johns Hopkins University · USMemorial Sloan Kettering Cancer Center · US

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Hongbiao Carl Lekaye · 1985 to 2026
$347.4M
Translational Research Central ServicesP30CA006973 · NCI · JOHNS HOPKINS UNIVERSITY · PI WILLIAM George NELSON · 1985 to 2026
$208.6M
Leveraging fructose transport to create a privileged substrate to selectively fuel T cellsR01CA248364 · NCI · SLOAN-KETTERING INST CAN RESEARCH · PI Kayvan R Keshari · 2021 to 2026
$4.3M
Development of large-field-of-view hyperpolarized MRIR01CA237466 · NCI · SLOAN-KETTERING INST CAN RESEARCH · PI CUNNINGHAM, CHARLES H., HRICAK, HEDVIG · 2020 to 2024
$3.4M
Visualizing oxidative stress using hyperpolarized magnetic resonanceR01CA252037 · NCI · SLOAN-KETTERING INST CAN RESEARCH · PI KESHARI, KAYVAN R · 2020 to 2024
$3.3M
Hyperpolarized Micro-NMR for Quantitative Analysis of Metabolism in Leukemia Stem CellsR00CA226357 · NCI · JOHNS HOPKINS UNIVERSITY · PI JEONG, SANGMOO · 2021 to 2023
$747k
uCoil NMR platform for robust and high-throughput analysis of in vitro metabolic flux on living cellsR21CA212958 · NCI · SLOAN-KETTERING INST CAN RESEARCH · PI KESHARI, KAYVAN R · 2017 to 2019
$660k
Leukemia Research Foundation N/ANCI NIH HHS P30 CA008748NCI NIH HHS R00 CA226357NIH HHS P30CA006973NIH HHS P30CA008748NIH HHS R00CA226357NIH HHS R01CA237466NIH HHS R01CA248364NIH HHS R01CA252037NIH HHS R21CA212958
6 · The paper itself

Abstract

Abnormal metabolism is a hallmark of cancer cells. Accumulating evidence suggests that metabolic changes are likely to occur before other cellular responses in cancer cells upon drug treatment. Therefore, the metabolic activity or flux in cancer cells could be a potent biomarker for cancer detection and treatment monitoring. Magnetic resonance (MR)-based sensing technologies have been developed with hyperpolarized molecules for real-time flux analysis, but they still suffer from low sensitivity and throughput. To address this limitation, we have developed an innovative miniaturized MR coil, termed micro-slab MR coil, for simultaneous analysis of metabolic flux in multiple samples. Combining this approach with hyperpolarized probes, we were able to quantify the pyruvate-to-lactate flux in two different leukemic cell lines in a non-destructive manner, simultaneously. Further, we were able to rapidly assess flux changes with drug treatment in a single hyperpolarization experiment. This new multi-sample system has the potential to transform our ability to assess metabolic dynamics at scale.

Indexed as

13C-magnetic resonancehyperpolarizationmetabolic fluxmicro-NMR coil

Identifiers

PMID36671586
PMCPMC9854444
OpenAlexW4313260376

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.