Evidence map›Paper›PMID 36669062›Full record

ArticleVeterinary sciences2023

Complications in Laparoscopic Access in Standing Horses Using Cannula and Trocar Units Developed for Human Medicine.

Francisco José Vázquez, Arantza Vitoria, Javier Gómez-Arrue, Sara Fuente, Laura Barrachina, Ignacio de Blas, Antonio Romero

Open access · goldAbstract read
In one paragraph

Article in Veterinary sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Francisco José VázquezEquine Surgery and Medicine Service, Veterinary Hospital (HVUZ), Universidad de Zaragoza, C/Miguel Servet 177, 50013 Zaragoza, Spain.ORCID 0000-0002-8712-2275
Arantza VitoriaEquine Surgery and Medicine Service, Veterinary Hospital (HVUZ), Universidad de Zaragoza, C/Miguel Servet 177, 50013 Zaragoza, Spain.ORCID 0000-0003-1286-4968
Javier Gómez-ArrueMinimally Invasive Techniques Research Unit (UTMI), Universidad de Zaragoza, C/Miguel Servet 177, 50013 Zaragoza, Spain.ORCID 0000-0001-9014-6457
Sara FuenteEquine Surgery and Medicine Service, Veterinary Hospital (HVUZ), Universidad de Zaragoza, C/Miguel Servet 177, 50013 Zaragoza, Spain.
Laura BarrachinaEquine Surgery and Medicine Service, Veterinary Hospital (HVUZ), Universidad de Zaragoza, C/Miguel Servet 177, 50013 Zaragoza, Spain.
Ignacio de BlasDepartment of Animal Pathology, Faculty of Veterinary, Universidad de Zaragoza, C/Miguel Servet 177, 50013 Zaragoza, Spain.
Antonio RomeroEquine Surgery and Medicine Service, Veterinary Hospital (HVUZ), Universidad de Zaragoza, C/Miguel Servet 177, 50013 Zaragoza, Spain.
Universidad de Zaragoza · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

First cannulation is a critical manoeuvre in equine laparoscopy. This retrospective study aimed at the comparison of the frequency and type of complications detected when using different human laparoscopy devices for laparoscopic access in standing horses, and the influence of body condition in such complications. Forty-four procedures were included, and retrieved data comprised cannula insertion technique, body condition, and type and frequency of complications. Laparoscopic access techniques were classified into five groups: P: pneumoperitoneum created using Veress needle prior to cannulation; T: sharp trocar; D: direct access via surgical incision; V: Visiport optical trocar and H: optical helical cannula (OHC). In groups T, D, V and H, access was achieved without prior induction of pneumoperitoneum. Complications were registered in 13/44 procedures, of which retroperitoneal insufflation was the most common (6/13). Statistically significant association was found between the complication incidence and the type of access, with group D showing the highest complication frequency (80%) and group H the lowest frequency (0%). The majority of complications (9/13) were observed in overweight horses. We conclude that devices designed for human patients can be used for laparoscopic access in standing horses, with the use of OHC minimizing the appearance of complications, especially in overweight horses with OW.

Indexed as

body conditioncomplicationsendotip cannulahorselaparoscopic accesslaparoscopyminimally invasive surgery

Identifiers

PMID36669062
PMCPMC9863198
OpenAlexW4316468270

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.