ArticleSports (Basel, Switzerland)2022
Comparison of the PUSH Band 2.0 and Vicon Motion Capture to Measure Concentric Movement Velocity during the Barbell Back Squat and Bench Press.
Article in Sports (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.
- Reliability, Device Agreement and Validity of Load-Velocity Profiles: A Systematic Review with Meta-analysis.Sports medicine - open · 2026Pooled it
- A predictive model for vertical ground reaction force during incline push-ups.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The purpose of this investigation was to compare concentric movement velocity (CMV) measured with the PUSH Band (v2.0) and a Vicon motion capture system (MC) during the back squat (SQ) and the bench press (BP) resistance exercises (RE). Twelve resistance-trained males (26.0 ± 5.5 years; 175.6 ± 4.9 cm; 96.3 ± 15.8 kg) completed ten repetitions at 50% of one-repetition maximum (1RM), and six repetitions at 75% 1RM for both BP and SQ. Four PUSH devices were utilized and attached to the subject’s right forearm, the center barbell, left and right sides of the barbell. MC markers were placed on top of each PUSH device. An overall analysis using a series of least-squares means contrasts suggested CMV did not differ (p > 0.05) between measurement technologies when position, RE, intensity and repetitions were combined. PUSH exhibited the highest Intraclass Correlation Coefficients (ICC = 0.835−0.961) and Pearson Product-Moment Correlation Coefficients (r = 0.742−0.949) at the arm and center barbell locations when compared with MC. The measurement of CMV between MC and PUSH compares favorably during moderate (i.e., 50%) and high (75%) intensity SQ and BP RE. These data indicate individuals can use the PUSH band v2.0 to accurately monitor CMV within a RE set for SQ and BP RE.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.