ArticleJournal of cardiovascular translational research2023

Inflow from a Cardiopulmonary Assist System to the Pulmonary Artery and Its Implications for Local Hemodynamics-a Computational Fluid Dynamics Study.

Kristin Hugenroth, Felix Krooß, Flutura Hima, Lasse Strudthoff, Rüdger Kopp, Jutta Arens, Sebastian Kalverkamp, Ulrich Steinseifer, Michael Neidlin, Jan Spillner

Open access · hybridAbstract read
In one paragraph

Article in Journal of cardiovascular translational research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 64% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Kristin HugenrothDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany. Kristin.Hugenroth@rwth-aachen.de.ORCID http://orcid.org/0000-0001-6672-4990
Felix KrooßDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
Flutura HimaDepartment of Thoracic and Cardiovascular Surgery, Medical Faculty, University Hospital, RWTH Aachen University, Aachen, Germany.
Lasse StrudthoffDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
Rüdger KoppDepartment of Intensive Care Medicine and Intermediate Care, Medical Faculty, University Hospital, RWTH Aachen University, Aachen, Germany.
Jutta ArensDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
Sebastian KalverkampDepartment of Thoracic and Cardiovascular Surgery, Medical Faculty, University Hospital, RWTH Aachen University, Aachen, Germany.
Ulrich SteinseiferDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
Michael NeidlinDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
Jan SpillnerDepartment of Thoracic and Cardiovascular Surgery, Medical Faculty, University Hospital, RWTH Aachen University, Aachen, Germany.
RWTH Aachen University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

When returning blood to the pulmonary artery (PA), the inflow jet interferes with local hemodynamics. We investigated the consequences for several connection scenarios using transient computational fluid dynamics simulations. The PA was derived from CT data. Three aspects were varied: graft flow rate, anastomosis location, and inflow jet path length from anastomosis site to impingement on the PA wall. Lateral anastomosis locations caused abnormal flow distribution between the left and right PA. The central location provided near-physiological distribution but induced higher wall shear stress (WSS). All effects were most pronounced at high graft flows. A central location is beneficial regarding flow distribution, but the resulting high WSS might promote detachment of local thromboembolisms or influence the autonomic nervous innervation. Lateral locations, depending on jet path length, result in lower WSS at the cost of an unfavorable flow distribution that could promote pulmonary vasculature changes. Case-specific decisions and further research are necessary.

Indexed as

HydrodynamicsPulmonary ArteryComputer SimulationHemodynamicsModels, CardiovascularStress, MechanicalArtificial lungCFD simulationECMOGraft connectionIn silicoLung perfusionRetrograde flow

Identifiers

PMID36662482
PMCPMC10480287
OpenAlexW4317567061

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.