Evidence map›Paper›PMID 36662415›Full record

ArticleInternational journal of computer assisted radiology and surgery2023

A hybrid hierarchical strategy for registration of 7T TOF-MRI to 7T PC-MRI intracranial vessel data.

Lena Spitz, Franziska Gaidzik, Daniel Stucht, Hendrik Mattern, Bernhard Preim, Sylvia Saalfeld

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 99% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Lena SpitzDepartment of Simulation and Graphics, Otto-von-Guericke University (OvGU), Magdeburg, Germany. lena.spitz@isg.cs.ovgu.de.ORCID http://orcid.org/0000-0002-4108-6918
Franziska GaidzikForschungscampus STIMULATE, Magdeburg, Germany.
Daniel StuchtDepartment of Biomedical Magnetic Resonance, OvGU, Magdeburg, Germany.
Hendrik MatternDepartment of Biomedical Magnetic Resonance, OvGU, Magdeburg, Germany.
Bernhard PreimDepartment of Simulation and Graphics, Otto-von-Guericke University (OvGU), Magdeburg, Germany.
Sylvia SaalfeldDepartment of Simulation and Graphics, Otto-von-Guericke University (OvGU), Magdeburg, Germany.
Otto-von-Guericke-Universität Magdeburg · DEMagna International (Germany) · DE

Funding

Bundesministerium für Bildung und Forschung 13GW0473ADeutsche Forschungsgemeinschaft SA 3461/3-1
6 · The paper itself

Abstract

purpose7T time-of-flight (TOF) MRI provides high resolution for the evaluation of cerebrovascular vessels and pathologies. In combination with 4D flow fields acquired with phase-contrast (PC) MRI, hemodynamic information can be extracted to enhance the analysis by providing direct measurements in the larger arteries or patient-specific boundary conditions. Hence, a registration between both modalities is required.

methodsTo combine TOF and PC-MRI data, we developed a hybrid registration approach. Vessels and their centerlines are segmented from the TOF data. The centerline is fit to the intensity ridges of the lower resolved PC-MRI data, which provides temporal information. We used a metric that utilizes a scaled sum of weighted intensities and gradients on the normal plane. The registration is then guided by decoupled local affine transformations. It is applied hierarchically following the branching order of the vessel tree.

resultsA landmark validation over Monte Carlo simulations yielded an average mean squared error of 184.73 mm and an average Hausdorff distance of 15.20 mm. The hierarchical traversal that transforms child vessels with their parents registers even small vessels not detectable in the PC-MRI.

conclusionThe presented work combines high-resolution tomographic information from 7T TOF-MRI and measured flow data from 4D 7T PC-MRI scan for the arteries of the brain. This enables usage of patient-specific flow parameters for realistic simulations, thus supporting research in areas such as cerebral small vessel disease. Automatization and free deformations can help address the limiting error measures in the future.

Indexed as

Magnetic Resonance AngiographyMagnetic Resonance ImagingArteriesBrainChildHumansPhase-contrast MRITime-of-flight MRIVascular co-registrationVessel centerline

Identifiers

PMID36662415
PMCPMC10113302
OpenAlexW4317567915

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked