ArticleGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2023
Real-time corneal thickness changes during phacoemulsification cataract surgery.
Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Characteristics and Factors of Incision-Related Descemet Membrane Detachment During Cataract Surgery: A Prospective Study.Ophthalmology and therapy · 2026Article
- Preoperative and Intraoperative Risk Factors for Short-Term Corneal Endothelial Cell Loss After Phacoemulsification in Dogs: A Comparative Study.Veterinary ophthalmology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
purposeTo observe the changes in corneal thickness during phacoemulsification cataract surgery and to analyze the influencing factors.
methodsOne hundred two patients (102 eyes) with cataracts undergoing phacoemulsification cataract surgery at Shandong Eye Hospital between July and October 2021 were included. Intraoperative OCT was applied to capture real-time images preoperatively, before and after ultrasonic emulsification, at the end of irrigation aspiration and the end of surgery. Then, the corneal thickness at the above time points was measured using Photoshop software.
resultsThe corneal thickness of 102 cataract patients was 511.79 ± 31.46 μm before operation and 512.71 ± 31.51 μm at the beginning of phacoemulsification, which increased by 0.91 ± 1.48 μm (0.2%). At the end of ultrasonic emulsification, the corneal thickness was 521.58 ± 32.75 μm and 8.87 ± 8.71 μm (1.7%) thicker than that before the procedure. After irrigation aspiration, the corneal thickness reached 528.09 ± 33.87 μm, which increased by 6.52 ± 6.38 μm (1.3%) compared with that of the previous step. At the end of the operation, the corneal thickness was 539.19 ± 33.88 μm, 11.09 ± 10.92 μm, and 27.37 ± 13.64 μm thicker than that of the previous step and the preoperative thickness, respectively, with an overall increase of 5.3%. The differences were statistically significant at all time points (all P < 0.001). Correlation analysis showed that postoperative corneal thickness changes were correlated with age, cataract lens nuclear grade, actual phacoemulsification time (APT), effective phacoemulsification time (EPT), average phacoemulsification energy (APE), total surgery time (TST), cell density (CD), maximum cell area (MAX), and cell area standard deviation (SD) (all P < 0.05), while the changes in thickness were not correlated with gender, cell area coefficient of variation (CV), percentage of hexagonal cells (6A), average cell area (AVE), or minimum cell area (MIN) (all P > 0.05).
conclusionsDuring phacoemulsification cataract surgery, corneal thickness gradually increases in real time with the increase of perfusion pressure and intraocular manipulation time. The real-time magnitude of intraoperative corneal thickness change is closely related to lens nucleus hardness, corneal endothelial cell density, ultrasound energy, and time for emulsification.