ArticleJournal of functional biomaterials2022
Insertion Torque, Removal Torque, and Resonance Frequency Analysis Values of Ultrashort, Short, and Standard Dental Implants: An In Vitro Study on Polyurethane Foam Sheets.
Article in Journal of functional biomaterials, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 29 citations in OpenAlex.
- Effect of Altered Cervical Thread Pitch on the Primary Stability of Dental Implants.Journal of clinical medicine · 2026Article
- Effect of Undersized Drilling and Sequential Osseodensification on Primary Implant Stability in Simulated Bone Types III and IV: An In Vitro Study.International journal of dentistry · 2026Article
- The Effect of Varying Abutment Heights on Stress Distribution in Different Bone Densities: A Finite Element Analysis Study.Materials (Basel, Switzerland) · 2025Article
- Influence of Drilling Protocol on Primary Implant Stability Depending on Different Bone Qualities and Implant Macro-Designs, Lengths, and Diameters.Journal of functional biomaterials · 2025Article
- The Influence of Insertion Torque on Stress Distribution in Peri-Implant Bones Around Ultra-Short Implants: An FEA Study.Journal of functional biomaterials · 2025Article
- Clinical and Microbiological Evaluation of 0.2% Tea Tree Oil Mouthwash in Prevention of Dental Biofilm-Induced Gingivitis.Dentistry journal · 2025Article
- Autologous and Heterologous Minor and Major Bone Regeneration with Platelet-Derived Growth Factors.Journal of functional biomaterials · 2025Review
- Influence of anaerobic adhesive on the resonance frequency analysis measured in abutments with external hexagon and conical connections: an in vitro study.Clinical oral investigations · 2024Article
- Article
- Neurological Complications following Surgical Treatments of the Lower Molars.International journal of dentistry · 2024Review
- Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols-An In Vitro Analysis.Journal of functional biomaterials · 2023Article
- Surface Coatings of Dental Implants: A Review.Journal of functional biomaterials · 2023Review
- A New Simplified Autogenous Sinus Lift Technique.Bioengineering (Basel, Switzerland) · 2023Article
- The Influence of Implant Macro-geometry in Primary Stability in Low-Density Bone: AnJournal of International Society of Preventive & Community DentistryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Short implants were introduced to reduce morbidity, treatment duration, and complex bone regeneration interventions in atrophic jaws and to improve patient-reported outcomes. This study aimed to determine the insertion torque (IT), removal torque (RT), and resonance frequency analysis (RFA) values of ultrashort (3 mm length), short (7 mm length), and standard implants (10 mm length) inserted in 1-, 2-, 3-, and 4-mm thickness polyurethane sheets with densities of 10, 20, and 30 pounds per cubic foot (PCF). Standard-length implants were the gold standard (control). Overall, short-length implant IT values were higher or similar to the control in most experimental conditions. Those inserted into a 3 mm/30 PCF lamina showed the highest IT values, whereas 5 mm diameter ultrashort-length implants inserted into 2 and 3 mm/20 PCF laminas were higher than other implants. RT values followed the same trend and RFA values were more appreciable in short- and standard-length implants in all the scenarios. However, ultrashort-length implants reached a primary stability comparable to that of standard implants in lower thicknesses. In conclusion, although further studies are needed to corroborate this in vitro model with preclinical and clinical studies, our data shed light on short- and ultrashort-length implants geometries to a potential application in critical atrophy of the posterior jaws.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.