Evidence map›Paper›PMID 36661916›Full record

ArticleJournal of cardiovascular development and disease2023

Increased Plasma Concentrations of Extracellular Vesicles Are Associated with Pro-Inflammatory and Pro-Thrombotic Characteristics of Left and Right Ventricle Mechanical Support Devices.

Tomasz Urbanowicz, Anna Olasińska-Wiśniewska, Kajetan Grodecki, Aleksandra Gąsecka, Krzysztof J Filipiak, Maciej Gawlikowski, Łukasz Mucha, Marek Jemielity

Abstract read
In one paragraph

Article in Journal of cardiovascular development and disease, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tomasz UrbanowiczCardiac Surgery and Transplantology Department, Poznan University of Medical Sciences, 61-848 Poznan, Poland.ORCID 0000-0001-8080-2764
Anna Olasińska-WiśniewskaCardiac Surgery and Transplantology Department, Poznan University of Medical Sciences, 61-848 Poznan, Poland.ORCID 0000-0002-4213-8708
Kajetan Grodecki1st Department of Cardiology, Medical University of Warsaw, 02-097 Warsaw, Poland.ORCID 0000-0002-0358-5679
Aleksandra Gąsecka1st Department of Cardiology, Medical University of Warsaw, 02-097 Warsaw, Poland.
Krzysztof J FilipiakInstitute of Clinical Science, Maria Sklodowska-Curie Medical Academy, 00-136 Warsaw, Poland.ORCID 0000-0002-6563-0877
Maciej GawlikowskiFaculty of Biomedical Engineering, Silesian University of Technology, 44-100 Gliwice, Poland.ORCID 0000-0002-6526-2656
Łukasz MuchaF.R.K. Intra-Cordis Professor Zbigniew Religa Foundation of Cardiac Surgery Development, 41-800 Zabrze, Poland.
Marek JemielityCardiac Surgery and Transplantology Department, Poznan University of Medical Sciences, 61-848 Poznan, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mechanical circulatory support (MCS) allows for functional left and right heart ventricle replacement. MCS induces a systemic inflammatory reaction and prothrombotic state leading to an increased risk of thrombus formation. The extracellular vesicles (EVs) are nanoparticles released from active/injured cells characterized by prothrombotic properties. Simple inflammatory parameters from whole blood count analysis have established a clinical role in everyday practice to describe immune-inflammatory activation. We hypothesized that increased plasma concentrations of EVs might be associated with the proinflammatory and pro-thrombotic characteristics of left ventricle assist device (LVAD) and right ventricle assist device (RVAD) devices. We presented a pilot study showing the concentration of peripheral blood serum, right and left ventricle mechanical assist device extracellular concentration in relation to thrombotic complication in patients treated with a biventricular pulsatile assist device (BIVAD). The observation was based on 12 replacements of pulsatile pumps during 175 days of observation. The proinflammatory characteristics of LVAD were noted. The proinflammatory and procoagulant activation by RVAD was observed. The results may provide possible explanations for the worse results of right-sided mechanical supports observed in clinical practice.

Indexed as

BIVAD 6left ventricular assist device 4mechanical circulatory support 5NLR 1SII 3SIRI 2

Identifiers

PMID36661916
PMCPMC9866833

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.