Evidence map›Paper›PMID 36660438›Full record

ArticlePulse (Basel, Switzerland)2022

Challenges Presented by Cuffless Measurement of Blood Pressure if Adopted for Diagnosis and Treatment of Hypertension.

Alberto Avolio, James Cox, Kyrollos Louka, Fatemeh Shirbani, Isabella Tan, Ahmad Qasem, Mark Butlin

Open access · diamondAbstract read
In one paragraph

Article in Pulse (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
1.4field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Practical Application of a New Cuffless Blood Pressure Measurement Method.Pathophysiology : the official journal of the International Society for Pathophysiology · 2023
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Alberto AvolioMacquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, New South Wales, Australia.
James CoxMacquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, New South Wales, Australia.
Kyrollos LoukaMacquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, New South Wales, Australia.
Fatemeh ShirbaniMacquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, New South Wales, Australia.
Isabella TanMacquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, New South Wales, Australia.
Ahmad QasemMacquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, New South Wales, Australia.
Mark ButlinMacquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, New South Wales, Australia.
Macquarie University · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The global health burden presented by hypertension is providing increased motivation for improved means of collection of blood pressure (BP) data. A growing area of research and commercial activity is the use of wearable devices to provide BP data using non-invasive cuffless techniques. The accelerated progress in recent years, particularly relating to connectivity of smartphone technology, has promoted the availability of consumer devices that provide values of BP. The main types of devices are wrist-worn, watch-type devices with sensors that typically record a photoplethysmography (PPG) signal, sometimes also with an electrocardiography (ECG) signal. The general underlying concept of the cuffless BP measurement in most device types is the association of BP and the travel time of the arterial pulse between two locations, determined from the time delay between the ECG and PPG signals. Other methods may involve additional analysis of the PPG waveform features. Experimental data are presented to illustrate the challenges presented by cuffless BP techniques in obtaining reliable BP measurements when the change in BP is caused by different stimuli affecting cardiac and vascular mechanisms. These effects influence the association of the measured and physiological BP change, thus presenting significant challenges and potential limitations in the use of cuffless BP devices for the diagnosis and treatment of hypertension.

Indexed as

Blood pressureHypertensionPulse transit timeVital signsWearable devices

Identifiers

PMID36660438
PMCPMC9843645
OpenAlexW4224242054

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked