ArticlePatient safety in surgery2023
Conversion hip arthroplasty for failed internal fixation of ipsilateral femoral neck and shaft fractures: a case report.
Article in Patient safety in surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 0 citations in OpenAlex.
- Finite element analysis of four different fixation methods for the treatment of ipsilateral femoral neck and shaft fractures.BMC musculoskeletal disorders · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIpsilateral femoral neck and hip fractures are uncommon high energy injuries. In the literature no single method of treatment has emerged as superior to the others. A recent publication has documented the successful application of the rendezvous technique using dual-implants for treating these injuries. However in some cases, this technique may fail and revision surgery is required. CASE PRESENTATION: A 67-year old man sustained ipsilateral fractures of his femur and femoral neck in a road traffic accident. His injuries were treated by a dual construct consisting of a retrograde femoral nail and dynamic hip screw. Three months after surgery the hip screw cut out of the femoral head necessitating revision to a total hip arthroplasty. Surgery was carried out using a single stage two part procedure on a standard operating table without having to reposition or redrape the patient. There were no postoperative complications and at 1 year from surgery the patient is satisfied with the result and has returned to work.
conclusionConversion hip arthroplasty in the presence of dual implants is a technically challenging and unpredictable procedure, with an increased risk of complications. Our surgical approach provides a framework for orthopedic surgeons to safely perform this complex procedure.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.