Evidence map›Paper›PMID 36657630›Full record

ArticleBone2023

Ultrashort Echo Time (UTE) MRI porosity index (PI) and suppression ratio (SR) correlate with the cortical bone microstructural and mechanical properties: Ex vivo study.

Saeed Jerban, Yajun Ma, Salem Alenezi, Dina Moazamian, Jiyo Athertya, Hyungseok Jang, Erik Dorthe, Darryl Dlima, Gina Woods, Christine B Chung and 2 more

Open access · greenAbstract read
In one paragraph

Article in Bone, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
3.7field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 16 citations in OpenAlex.

  1. Development and assessment of anImaging science in dentistry · 2026
    Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Ultrashort echo time MRI detects significantly lower collagen but higher pore water in the tibial cortex of female patients with osteopenia and osteoporosis.Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research · 2024
    Article
  7. Article
  8. Article
  9. Bone Biomarkers Based on Magnetic Resonance Imaging.Seminars in musculoskeletal radiology · 2024
    Review
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 4 institutions in 2 countries.

Saeed JerbanDepartment of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA; Department of Orthopedic Surgery, University of California, San Diego, La Jolla, CA, USA. Electronic address: sjerban@health.ucsd.edu.
Yajun MaDepartment of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA.
Salem AleneziResearch and Laboratories Sector, Saudi Food and Drug Authority, Riyadh, Kingdom of Saudi Arabia.
Dina MoazamianDepartment of Radiology, University of California, San Diego, La Jolla, CA, USA.
Jiyo AthertyaDepartment of Radiology, University of California, San Diego, La Jolla, CA, USA.
Hyungseok JangDepartment of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA.
Erik DortheShiley Center for Orthopedic Research and Education at Scripps Clinic, La Jolla, CA, USA.
Darryl DlimaShiley Center for Orthopedic Research and Education at Scripps Clinic, La Jolla, CA, USA.
Gina WoodsDepartment of Medicine, University of California, San Diego, La Jolla, CA, USA.
Christine B ChungDepartment of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA.
Eric Y ChangDepartment of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA.
Jiang DuDepartment of Radiology, University of California, San Diego, La Jolla, CA, USA; Radiology Service, Veterans Affairs San Diego Healthcare System, San Diego, La Jolla, CA, USA. Electronic address: jiangdu@health.ucsd.edu.
University of California, San Diego · USVA San Diego Healthcare System · USScripps Clinic · USSaudi Arabian Monetary Authority · SA

Funding

Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of BoneR01AR068987 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DU, JIANG · 2015 to 2024
$4.9M
Quantitative UTE MR Imaging: Sensitive Biomarkers for OsteoarthritisR01AR062581 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DU, JIANG · 2013 to 2022
$4.1M
Resource-based Center for the study of the joint microenvironment in rheumatology (Overall Application)P30AR073761 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI FIRESTEIN, GARY S · 2018 to 2022
$3.9M
Ultrashort Echo Time Magnetic Resonance Imaging of the Lumbar Intervertebral Disc.R01AR079484 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI Yajun Ma · 2022 to 2026
$2.7M
Ultrashort Echo Time Magnetic Resonance Imaging of Hemophilic ArthropathyR01AR078877 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI JANG, HYUNGSEOK · 2021 to 2025
$2.4M
Three-dimensional Ultrashort Echo Time Magnetic Resonance Imaging of EnthesesR01AR075825 · NIAMS · VETERANS MEDICAL RESEARCH FDN/SAN DIEGO · PI CHANG, ERIC Y · 2019 to 2023
$1.8M
Knee evaluation under mechanical loading by cones ultrashort echo time MR imagingK01AR080257 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI saeed jerban · 2022 to 2026
$602k
Quantitative Measurement of Joint pH with Magnetic Resonance ImagingI01RX002604 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHANG, ERIC Y · 2018 to 2022
–
Quantitative Magnetic Resonance Imaging of Human Rotator Cuff TendonI01CX001388 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHANG, ERIC Y · 2016 to 2024
–
Ultrashort TE MR Imaging of Femorotibial CartilageI01CX000625 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHRISTINE B CHUNG · 2012 to 2026
–
CSRD VA I01 CX000625CSRD VA I01 CX001388NIAMS NIH HHS K01 AR080257NIAMS NIH HHS P30 AR073761NIAMS NIH HHS R01 AR062581NIAMS NIH HHS R01 AR068987NIAMS NIH HHS R01 AR075825NIAMS NIH HHS R01 AR078877NIAMS NIH HHS R01 AR079484RRD VA I01 RX002604
6 · The paper itself

Abstract

Ultrashort echo time (UTE) MRI can image and consequently enable quantitative assessment of cortical bone. UTE-MRI-based evaluation of bone is largely underutilized due to the high cost and time demands of MRI in general. The signal ratio in dual-echo UTE imaging, known as porosity index (PI), as well as the signal ratio between UTE and inversion recovery UTE (IR-UTE) imaging, known as the suppression ratio (SR), are two rapid UTE-based bone evaluation techniques (∼ 5 mins scan time each), which can potentially reduce the time demand and cost in future clinical studies. This study aimed to investigate the correlations of PI and SR measures with cortical bone microstructural and mechanical properties. Cortical bone strips (n = 135) from tibial and femoral midshafts of 37 donors (61 ± 24 years old) were scanned using a dual-echo 3D Cones UTE sequence and a 3D Cones IR-UTE sequence for PI and SR calculations, respectively. Average bone mineral density, porosity, and pore size were measured using microcomputed tomography (μCT). Bone mechanical properties were measured using 4-point bending tests. The μCT measures showed significant correlations with PI (moderate to strong, R = 0.68-0.71) and SR (moderate, R = 0.58-0.68). Young's modulus, yield stress, and ultimate stress demonstrated significant moderate correlations with PI and SR (R = 0.52-0.62) while significant strong correlations with μCT measures (R > 0.7). PI and SR can potentially serve as fast and noninvasive (non-ionizing radiation) biomarkers for evaluating cortical bone in various bone diseases.

Indexed as

Bone and BonesCortical BoneImaging, Three-DimensionalMagnetic Resonance ImagingPorosityX-Ray MicrotomographyBone mechanicsCortical boneMRIPorosity indexSuppression ratioUltrashort echo time

Identifiers

PMID36657630
PMCPMC9987215
OpenAlexW4317568239

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.