Evidence map›Paper›PMID 36655199›Full record

ArticlePathogens & immunity2022

Evaluation of Interventions to Improve Ventilation in Households to Reduce Risk for Transmission of Severe Acute Respiratory Syndrome Coronavirus 2.

Wilson Ha, Mitchell A Stiefel, Jeremy R Gries, Jennifer L Cadnum, Maria M Torres-Teran, Brigid M Wilson, Curtis J Donskey

Open access · diamondAbstract read
In one paragraph

Article in Pathogens & immunity, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 6 institutions in 1 country.

Wilson HaJohn Carroll University, University Heights, Ohio.
Mitchell A StiefelThe Ohio State University, Columbus, Ohio.
Jeremy R GriesSt. Louis University, St. Louis, Ohio.
Jennifer L CadnumResearch Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio.
Maria M Torres-TeranResearch Service, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio.
Brigid M WilsonGeriatric Research, Education, and Clinical Center, Louis Stokes Cleveland VA Medical Center, Cleveland, Ohio.
Curtis J DonskeyCase Western Reserve University School of Medicine, Cleveland, Ohio.
Louis Stokes Cleveland VA Medical Center · USGeriatric Research Education and Clinical Center · USJohn Carroll University · USSaint Louis University · USThe Ohio State University · USUniversity School · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Inadequate ventilation may contribute to the high risk for household transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Methods: We evaluated the effectiveness of several interventions recommended to improve ventilation in households. In 7 residential homes, carbon dioxide monitoring was conducted to assess ventilation in occupied open areas such as family rooms and in bedrooms and/or offices. Carbon dioxide levels above 800 parts per million (ppm) were considered an indicator of suboptimal ventilation for the number of people present. In 1 of the 7 homes, various interventions to improve ventilation or to filter air were assessed in a kitchen area by measuring clearance of aerosol particles produced using an aerosol-based spray system and carbon dioxide generated by cooking with a gas stove. Results: Carbon dioxide levels rose above 800 ppm in bedrooms and offices with 2 occupants when windows and doors were closed and in open areas during gatherings of 5 to 10 people; carbon dioxide levels decreased when windows or doors were opened. Clearance of carbon dioxide and aerosol particles significantly increased with interventions including running fans, operating portable air cleaners, and opening windows, particularly when there was a noticeable breeze or when a window fan was used to blow contaminated air outside. Conclusion: In households, several measures to improve ventilation or air filtration were effective in reducing carbon dioxide accumulation or enhancing clearance of carbon dioxide and aerosol particles. Studies are needed to determine if interventions to improve ventilation can reduce the risk for airborne transmission of SARS-CoV-2 in households.

Indexed as

aerosolair cleanercarbon dioxideSARS-CoV-2ventilation

Identifiers

PMID36655199
PMCPMC9836208
OpenAlexW4311038688

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked