Evidence map›Paper›PMID 36654650›Full record

ArticleCureus2022

Gastric Emptying and Its Correlation With Weight Loss and Body Mass Index in Patients With an Intragastric Balloon: A Prospective Study With Six Years of Follow-Up.

Sérgio Barrichello, Igor Braga Ribeiro, Thiago F de Souza, Manoel Dos Passos Galvão Neto, Eduardo Grecco, Jaques Waisberg

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Sérgio BarrichelloDepartment of Gastrointestinal Surgery, Faculdade de Medicina do ABC (FMABC), Santo André, BRA.
Igor Braga RibeiroServiço de Endoscopia Gastrointestinal do Departamento de Gastroenterologia, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, Sao Paulo, BRA.
Thiago F de SouzaDepartment of Gastrointestinal Surgery, Faculdade de Medicina do ABC (FMABC), Santo André, BRA.
Manoel Dos Passos Galvão NetoDepartment of Gastrointestinal Surgery, Faculdade de Medicina do ABC (FMABC), Santo André, BRA.
Eduardo GreccoDepartment of Gastrointestinal Surgery, Faculdade de Medicina do ABC (FMABC), Santo André, BRA.
Jaques WaisbergDepartment of Gastrointestinal Surgery, Faculdade de Medicina do ABC (FMABC), Santo André, BRA.
Faculdade de Medicina do ABC · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Obesity is the most well-established and prolonged pandemic in modern society. Having a better understanding of the available tools is important to improve weight loss and make the strategies more productive. This study aims to evaluate the effect of intragastric balloon (IGB) on gastric emptying time, its relationship with weight loss after IGB removal, and weight maintenance after six years. Methodology This prospective study analyzed data from patients undergoing IGB placement. A six-years follow-up was performed and data about weight maintenance were collected. We analyzed the impact of the IGB on gastrointestinal motility and its correlation with weight loss. Results Of the 20 patients included in the study, 52.4% were diagnosed with class I obesity and 47.6% with class II obesity. The mean weight of the patients was 96.5 ± 11.9 kg at baseline, 79.6 ± 11.4 kg at the time of IGB removal, 81.8 ± 9.1 kg at six months, and 93.2 ± 14.3 kg six years after IGB removal. The mean difference between the initial weight and that measured immediately after IGB removal was 16.68 ± 5.71 kg. Regarding gastric emptying time, there was a difference in retention on comparing the measurement before balloon placement to that after the balloon was in place (72.9% vs. 86.8%) after one hour of food intake. Comparing two hours after food intake, patients before IGB placement had a 30.6% food retention, while patients with IGB in place had a 69.2% retention. Conclusions In patients with class I or II obesity, the use of an IGB delayed gastric emptying of foods but showed no direct correlation with weight loss. Weight loss achieved after IGB placement was maintained in half of the patients at a six-year follow-up.

Indexed as

gastric balloongastric emptyingintragastric balloonobesityweight loss

Identifiers

PMID36654650
PMCPMC9840869
OpenAlexW4311685224

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.