Evidence map›Paper›PMID 36650554›Full record

Observational studyJournal of cardiothoracic surgery2023

Study of the accuracy of a radial arterial pressure waveform cardiac output measurement device after cardiac surgery.

Pilar Ordoñez-Rufat, Nuria Mancho-Fora, Cristian Tebe-Cordomi, Victoria Polit-Martinez, Ricardo Abellan-Lencina, Joaquin Fernandez-Alvarez, Juan Carlos Lopez-Delgado

Open access · goldAbstract readObservational StudyCase Reports
In one paragraph

Observational study in Journal of cardiothoracic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
0.3field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it, 1 citations in OpenAlex.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Pilar Ordoñez-RufatIntensive Care Department, Bellvitge University Hospital, C/ Feixa Llarga s/n, 08907, Hospitalet de Llobregat, Barcelona, Spain. pordonezr@gmail.com.ORCID http://orcid.org/0000-0002-8076-9930
Nuria Mancho-ForaBiostatistics Department, Universitat de Barcelona, Campus Bellvitge, Av. Mare de Déu de Bellvitge, 3, 08907, Hospitalet de Llobregat, Barcelona, Spain.
Cristian Tebe-CordomiBiostatistics Department, Universitat de Barcelona, Campus Bellvitge, Av. Mare de Déu de Bellvitge, 3, 08907, Hospitalet de Llobregat, Barcelona, Spain.
Victoria Polit-MartinezIntensive Care Department, Bellvitge University Hospital, C/ Feixa Llarga s/n, 08907, Hospitalet de Llobregat, Barcelona, Spain.
Ricardo Abellan-LencinaIntensive Care Department, Bellvitge University Hospital, C/ Feixa Llarga s/n, 08907, Hospitalet de Llobregat, Barcelona, Spain.
Joaquin Fernandez-AlvarezIntensive Care Department, Bellvitge University Hospital, C/ Feixa Llarga s/n, 08907, Hospitalet de Llobregat, Barcelona, Spain.
Juan Carlos Lopez-DelgadoIntensive Care Department, Bellvitge University Hospital, C/ Feixa Llarga s/n, 08907, Hospitalet de Llobregat, Barcelona, Spain.
Bellvitge University Hospital · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLess invasive monitoring, such as radial arterial pulse contour analysis (ProAQT® sensor), represents an alternative when hemodynamic monitoring is necessary to guide postoperative management and invasive monitoring is not technically feasible. The aim of the study is to evaluate the accuracy of the ProAQT® sensor cardiac output measurements in comparison with Pulmonary Artery Catheter (PAC) during the postoperative course of patients who underwent cardiac surgery with cardiopulmonary bypass. CASE PRESENTATION: Prospective observational study in a Surgical Intensive Care Unit of a tertiary university hospital. Ten patients with a mean age of 73.5 years were included. The main comorbidities were hypertension, diabetes, dyslipidemia and the preoperative left ejection fraction was 43.8 ± 14.5%. Regarding the type of surgery, six patients underwent valve surgery, two underwent coronary artery bypass grafting and two underwent aortic surgery. The cardiac index measured simultaneously by the ProAQT® sensor was compared with the PAC. The parameters were evaluated at predefined time points during the early postoperative courses (6 h, 12 h, 24 h, 48 h and 72 h). The degree of agreement with the cardiac index between the PAC and the ProAQT® sensor along the time points was measured using the concordance correlation coefficient, Bland-Altman analysis, and four-quadrant plot. Sixty-three pairs of measurements were analyzed. We showed that measurements of cardiac index were slightly higher with PAC (β ̂ = - 0.146, p-value = 0.094). The concordance correlation coefficient for the additive model of cardiac index was 0.64 (95% Confidence Interval: 0.36, 0.82), indicating a high concordance between both sensors. Bland-Altmann analysis showed a mean bias of 0.45 L·min

conclusionsIn patients undergoing cardiac surgery, the ProAQT® sensor may be useful to monitor cardiac index during the postoperative period, especially when more invasive monitoring is not possible.

Indexed as

Arterial PressureCardiac Surgical ProceduresAgedCardiac OutputCoronary Artery BypassHumansMonitoring, IntraoperativeReproducibility of ResultsArterial pulse contour analysisCardiac surgeryHemodynamic monitoringPulmonary artery catheter

Identifiers

PMID36650554
PMCPMC9843904
OpenAlexW4316810649

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.