ArticleBMC musculoskeletal disorders2023
Biomechanical study of the stiffness of the femoral locking compression plate of an external fixator for lower tibial fractures.
Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 6 citations in OpenAlex.
- Staged screw removal in external plate fixation for distal tibial fractures: a finite element study on adaptive biomechanics.Scientific reports · 2026Article
- Biomechanical evaluation of X-ray permeable CF/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis.Scientific reports · 2026Article
- A Modified External Fixation Device for Treating Open Fractures of the Lower Extremities: Two Case Reports.Case reports in orthopedics · 2026Article
- Effect of Screw Distribution on Stability and Interfragmentary Strain of Lower Tibial Fractures: A Finite Element Analysis.Current medical science · 2025Article
- A novel external fixation for treating tibial fractures: a finite element and biomechanical study.Journal of orthopaedic surgery and research · 2025Article
- Locking compression plate as a sequential external fixator following the distraction phase for the treatment of tibial bone defects caused by fracture-related infection: experiences from 22 cases.BMC musculoskeletal disorders · 2024Article
- Finite Element Analysis of Von Mises Stress in External Fixators for Open Tibial Fractures: A Comparative Study of ASTM F1541-02 and Tibia-Based Models in Indonesian Patients.Healthcare technology lettersArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundA locking compression plate (LCP) of the distal femur is used as an external fixator for lower tibial fractures. However, in clinical practice, the technique lacks a standardized approach and a strong biomechanical basis for its stability.
methodsIn this paper, internal tibial LCP fixator (Group IT-44), external tibial LCP fixator (Group ET-44), external distal femoral LCP fixator (Group EF-44, group EF-33, group EF-22), and conventional external fixator (Group CEF-22) frames were used to fix unstable fracture models of the lower tibial segment, and anatomical studies were performed to standardize the operation as well as to assess the biomechanical stability and adjustability of the distal femoral LCP external fixator by biomechanical experiments.
resultsIt was found that the torsional and flexural stiffnesses of group EF-44 and group EF-33 were higher than those of group IT-44 and group ET-44 (p < 0.05); the flexural stiffness of group EF-22 was similar to that of group IT-44 (p > 0.05); and the compressive stiffness of all three EF groups was higher than that of group ET-44 (p < 0.05). In addition, the flexural and compressive stiffnesses of the three EF groups decreased with the decrease in the number of screws (p < 0.05), while the torsional stiffness of the three groups did not differ significantly between the two adjacent groups (p > 0.05). Group CEF-22 showed the highest stiffnesses, while group ET-44 had the lowest stiffnesses (P < 0.05).
conclusionsThe study shows that the distal femoral LCP has good biomechanical stability and adjustability and is superior to the tibial LCP as an external fixator for distal tibial fractures, as long as the technique is used in a standardized manner according to the anatomical studies in this article.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.