Evidence map›Paper›PMID 36648989›Full record

ArticleTomography (Ann Arbor, Mich.)2022

Reduction in Radiation Exposure in Minimally Invasive Pedicle Screw Placement Using a Tubular Retractor: A Pilot Study.

Takeshi Oki, Alan Kawarai Lefor, Kentaro Nakamura, Takahiro Higashi, Isao Oki

Open access · goldAbstract read
In one paragraph

Article in Tomography (Ann Arbor, Mich.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Takeshi OkiDepartment of Orthopedic Surgery, Yuki Hospital, 9629-1 Yuki, Yuki-City 307-0001, Ibaraki, Japan.ORCID 0000-0002-4523-9299
Alan Kawarai LeforDepartment of Surgery, Division of Gastroenterological, General and Transplant Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke-City 329-0498, Tochigi, Japan.ORCID 0000-0001-6673-5630
Kentaro NakamuraDepartment of Orthopedic Surgery, Yuki Hospital, 9629-1 Yuki, Yuki-City 307-0001, Ibaraki, Japan.
Takahiro HigashiDepartment of Orthopedic Surgery, Shin Oyama City Hospital, 2251-1 Hitotonoya, Oyama-City 323-0827, Tochigi, Japan.
Isao OkiDepartment of Orthopedic Surgery, Yuki Hospital, 9629-1 Yuki, Yuki-City 307-0001, Ibaraki, Japan.
Jichi Medical University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivesPercutaneous pedicle screw (PPS) placement is a minimally invasive spinal procedure that has been rapidly adopted over the last decade. However, PPS placement has elicited fear of increased radiation exposure from some surgeons, medical staff, and patients. This is because PPS placement is performed using a K-wire, and the operator must perform K-wire insertion into the pedicle under fluoroscopy. In order to prevent erroneous insertion, there are many occasions when direct insertion is required during radiation exposure, and the amount of radiation exposure to hands and fingers in particular increases. Although these problems are being addressed by navigation systems, these systems are still expensive and not widely available. Attempts have been made to address this situation using instrumentation commonly used in spinal surgery. First, it was considered to visualize anatomical bone markers using a tubular retractor and a microscope. In addition, the use of a self-drilling pin was adopted to locate the pedicle in a narrower field of view. Based on these considerations, a minimally invasive and highly accurate pedicle screw placement technique was developed while avoiding direct radiation exposure. This study evaluated radiation exposure and accuracy of pedicle screw placement using this new procedure in one-level, minimally invasive, transforaminal lumbar interbody fusion (MIS-TLIF). MATERIALS AND

methodsData were collected retrospectively to review pedicle screw placement in single-level MIS TLIFs using a tubular retractor under a microscope. The total fluoroscopy time, radiation dose, and screw placement accuracy were reviewed. Extension of operating time was also evaluated.

resultsTwenty-four patients underwent single-level MIS TLIFs, with placement of 96 pedicle screws. There were 15 females and 9 males, with an average age of 64.8 years and a mean body mass index of 25.5 kg/m

conclusionsThis novel pedicle screw insertion technique compares favorably with other reports in terms of radiation exposure reduction and accuracy and is also useful from the viewpoint of avoiding direct radiation exposure to hands and fingers. It is economical because it uses existing spinal surgical instrumentation.

Indexed as

Pedicle ScrewsRadiation ExposureSpinal FusionFemaleHumansLumbar VertebraeMaleMiddle AgedMinimally Invasive Surgical ProceduresPilot ProjectsRetrospective Studiesminimally invasive spine stabilization (MISt)percutaneous pedicle screws (PPS)radiation protection

Identifiers

PMID36648989
PMCPMC9844279
OpenAlexW4312071182

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.