Evidence map›Paper›PMID 36648573›Full record

ArticleThe international journal of cardiovascular imaging2023

Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population.

Makoto Orii, Misato Sone, Takeshi Osaki, Kei Kikuchi, Tsuyoshi Sugawara, Xucheng Zhu, Martin A Janich, Atsushi Nozaki, Kunihiro Yoshioka

Abstract read
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Clinical utility of a rapid two-dimensional balanced steady-state free precession sequence with deep learning reconstruction.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 2 countries.

Makoto OriiDepartment of Radiology, Iwate Medical University, 2-1-1, Idaidori, Yahaba, 028-3695, Iwate, Japan. kori931@gmail.com.
Misato SoneDepartment of Radiology, Iwate Medical University, 2-1-1, Idaidori, Yahaba, 028-3695, Iwate, Japan.
Takeshi OsakiDepartment of Radiology, Iwate Medical University, 2-1-1, Idaidori, Yahaba, 028-3695, Iwate, Japan.
Kei KikuchiDepartment of Radiology Service, Iwate Medical University, Iwate, Japan.
Tsuyoshi SugawaraDepartment of Radiology Service, Iwate Medical University, Iwate, Japan.
Xucheng ZhuGE Healthcare, Menlo Park, CA, USA.
Martin A JanichGE Healthcare, Munich, Germany.
Atsushi NozakiGE Healthcare, Tokyo, Japan.
Kunihiro YoshiokaDepartment of Radiology, Iwate Medical University, 2-1-1, Idaidori, Yahaba, 028-3695, Iwate, Japan.
Iwate Medical University · JPSiemens Healthcare (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to assess the image quality and accuracy of respiratory-gated real-time two-dimensional (2D) cine incorporating deep learning reconstruction (DLR) for the quantification of biventricular volumes and function compared with those of the standard reference, that is, breath-hold 2D balanced steady-state free precession (bSSFP) cine, in an adult population. Twenty-four patients (15 men, mean age 50.7 ± 16.5 years) underwent cardiac magnetic resonance for clinical indications, and 2D DLR and bSSFP cine were acquired on the short-axis view. The image quality scores were based on three main criteria: blood-to-myocardial contrast, endocardial edge delineation, and presence of motion artifacts throughout the cardiac cycle. Biventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed. The 2D DLR cine had significantly shorter scan time than bSSFP (41.0 ± 11.3 s vs. 327.6 ± 65.8 s; p < 0.0001). Despite an analysis of endocardial edge definition and motion artifacts showed significant impairment using DLR cine compared with bSSFP (p < 0.01), the two sequences demonstrated no significant difference in terms of biventricular EDV, ESV, SV, and EF (p > 0.05). Moreover, the linear regression yielded good agreement between the two techniques (r ≥ 0.76). However, the LVM was underestimated for DLR cine (109.8 ± 34.6 g) compared with that for bSSFP (116.2 ± 40.2 g; p = 0.0291). Respiratory-gated 2D DLR cine is a reliable technique that could be used in the evaluation of biventricular volumes and function in an adult population.

Indexed as

Deep LearningAdultAgedHumansMagnetic Resonance Imaging, CineMaleMiddle AgedPredictive Value of TestsReproducibility of ResultsStroke VolumeVentricular FunctionBalanced steady-state free precessionCardiac magnetic resonance imagingRespiratory-gated real-time two-dimensional cine incorporating deep learning reconstructionVentricular function

Identifiers

PMID36648573
OpenAlexW4316810626

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.