Evidence map›Paper›PMID 36648539›Full record

Observational studyArchives of orthopaedic and trauma surgery2023

Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty.

Felix Riechelmann, H Lettner, R Mayr, R Tandogan, D Dammerer, M Liebensteiner

Abstract readObservational Study
In one paragraph

Observational study in Archives of orthopaedic and trauma surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Felix RiechelmannDepartment of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria. felix.riechelmann@i-med.ac.at.ORCID http://orcid.org/0000-0002-8157-0552
H LettnerMedical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
R MayrDepartment of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
R TandoganOrtoklinik, Ankara, Turkey.
D DammererUniversity Hospital Krems, Krems, Austria.
M LiebensteinerDepartment of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo analyze the match between preoperatively determined implant size (2D templating) and intraoperatively used implant size in total knee arthroplasty (TKA). Also examined were the factors that might influence templating accuracy (gender, surgeon experience, obesity, etc.). MATERIALS AND

methodsThe study was retrospective and conducted in a specialized ENDOCERT arthroplasty center. Digital templating was done with the MediCAD software. If the planned and implanted TKA components (both femur and tibia) were the same size, the match was classified "exact." A deviation of ± one size (at the femur or tibia or both) was classified "accurate." A deviation of ± two or more sizes (at the femur or tibia or both) was classified "inaccurate." Obesity, gender, implant type and surgeon experience were investigated for potential influence on templating accuracy. Chi-square tests and Cohen's weighted kappa test were used for statistical analysis.

resultsA total of 482 cases [33.6% male, 66.4% female, age 69 ± 11, body mass index (BMI) 30.3 ± 5.8] were included. When the femur and tibia were taken together, exact size match was observed in 34% (95% CI 29.9-38.3%) of cases, accurate size match in 57.5% (95% CI 53-61.8%) and inaccurate size match in 8.5% (95% CI 6.3-11.2%). Inaccurate size match prolonged operative time (p = 0.028). Regarding the factors potentially influencing templating accuracy, only gender had a significant influence, with templating being more accurate in men (p = 0.004). BMI had no influence on accuracy (p = 0.87). No effect on accuracy was observed for implant type and surgeon experience.

conclusionsThe accuracy of 2D size templating in TKA is low, even in a specialized ENDOCERT arthroplasty center. The study findings challenge the usefulness of preoperative 2D size templating and highlight the importance of more reliable templating methods. LEVEL OF EVIDENCE: Level III (retrospective observational study).

Indexed as

Arthroplasty, Replacement, HipArthroplasty, Replacement, KneeKnee ProsthesisAgedAged, 80 and overFemaleFemurHumansMaleMiddle AgedObesityPreoperative CareRetrospective StudiesAccuracyDigital templatingEndoCertOperative timeStorage costTotal knee arthroplasty

Identifiers

PMID36648539
PMCPMC10374828

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.