Evidence map›Paper›PMID 36644857›Full record

ArticleOrthopaedic surgery2023

Mid- to Long-term Follow-up of Severe Acetabular Bone Defect after Revision Total Hip Arthroplasty Using Impaction Bone Grafting and Metal Mesh.

Chao Yang, Kechao Zhu, Huiyong Dai, Xianlong Zhang, Qiaojie Wang, Qi Wang

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.5field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Chao YangDepartment of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.
Kechao ZhuDepartment of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.
Huiyong DaiDepartment of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.
Xianlong ZhangDepartment of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.
Qiaojie WangDepartment of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.
Qi WangDepartment of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai, China.ORCID https://orcid.org/0000-0001-7699-2518
Shanghai Jiao Tong University · CN

Funding

Shanghai Sailing Program 21YF1433800
6 · The paper itself

Abstract

objectiveIn revision total hip arthroplasty (THA), reconstruction of severe acetabular bone defect continues to be problematic for orthopedic surgeons. This study reports the mid- to long-term survivorship, radiological outcomes, and complications of impaction bone grafting (IBG) and metal mesh with a cemented acetabular component in the reconstruction of severe acetabular bone defects in revision THA.

methodsThis retrospective consecutive study included 26 patients (29 hips: type II B, four; type II C, three; type III A, 10; and type III B, 12) who underwent revision THA, which was performed using IBG and metal mesh, between 2007 and 2014 in our institution. All patients were followed up regularly for clinical and radiographical assessments. Migration and loosening of prosthesis graft integration and complications were observed and analyzed. Survival analysis was performed using a Kaplan-Meier survival analysis.

resultsAt the time of revision, 75.9% of the hips (22 hips) were classified as type III bone defects. The average follow-up period was 9.4 ± 2.8 (range, 2.4-14.0) years. Of the 29 hips, four hips (13.8%) were assessed as clinical failures; at the last follow-up, two had undergone re-revision THA, and two had not been scheduled for re-revision THA despite radiological failure of the acetabular component. Among them, three clinical failures (10.3%) were due to aseptic loosening, and one (3.4%) was due to infection. Radiographic evaluation showed bone graft integration in all hips during the follow-up. The Kaplan-Meier survivorship analysis revealed an acetabular reconstruction survival rate of 86.5% (95% confidence interval, 61.4%-95.7%) at 10 years.

conclusionIBG and metal mesh with a cemented acetabular component for revision THA is an effective technique for treating severe acetabular bone defects, with effective mid- to long-term outcomes due to the solid reconstruction of the acetabular bone defect and restoration of the hip rotation center.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisAcetabulumBone TransplantationFollow-Up StudiesHumansProsthesis FailureReoperationRetrospective StudiesSurgical MeshTreatment OutcomeAcetabular bone defectsCemented acetabular componentImpaction bone graftingMetal meshRevision total hip arthroplasty

Identifiers

PMID36644857
PMCPMC9977582
OpenAlexW4316466401

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.