ArticleIEEE transactions on radiation and plasma medical sciences2023
Timing, Energy, and 3-D Spatial Resolution of the BING PET Detector Module.
Article in IEEE transactions on radiation and plasma medical sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Semi-Monolithic Detectors for TOF-DOI Brain PET: Optimization of Time, Energy, and Positioning Resolutions With Varying Surface Treatments.IEEE transactions on radiation and plasma medical sciences · 2026Article
- A Time-Walk and Timing-Shift Correction Method for Dual-Ended Readout TOF-DOI PET Detectors.IEEE transactions on radiation and plasma medical sciences · 2025Article
- PET detectors with depth-of-interaction and time-of-flight capabilities.Radiological physics and technology · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
We evaluated the 3D spatial, energy, and timing resolution of the Brain (or Breast)-Initiative Next-Generation (BING) PET detector. The BING detector is an array of 1-mm-thick slats of LYSO scintillator with lapped specular-reflective faces (15-mm by 52-mm) that are stacked together and oriented with their long-narrow edges normal to the imaging field of view. Interaction positions are determined from the signals of silicon-photomultiplier (SiPM) arrays placed on the entrance (top) and exit (bottom) faces. The SiPM arrays are offset to determine the slat of interaction (SOI) without requiring any optical light sharing between slats. Maximum likelihood 2D location within the SOI is determined using the sensor signals. Interaction time is determined with a modified first-optical-photon pickoff method. Performance of the BING detector was measured as a function of position using a sideways coincidence-collimated beam. Slats were accurately identified, with an effective tangential detector resolution of 1 mm. Average resolutions (and ranges) are: 0.96 mm (0.85 mm to 1.11 mm) for lateral (axial) detector resolution, 1.6 mm (1.0 mm to 2.1 mm) for depth resolution, 13.6% (12.7% to 16.0%) for energy resolution, and 317 ps (241 ps to 404 ps) for coincidence timing resolution. Initial spatial and timing resolution results demonstrated that the BING detector can be effective in a small field-of view (e.g., brain or breast) PET system.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.