Evidence map›Paper›PMID 36644761›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2023

Timing, Energy, and 3-D Spatial Resolution of the BING PET Detector Module.

William Hunter, Sergei Dolinsky, Paul Kinahan, Robert Miyaoka

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. A Time-Walk and Timing-Shift Correction Method for Dual-Ended Readout TOF-DOI PET Detectors.IEEE transactions on radiation and plasma medical sciences · 2025
    Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

William HunterWilliam Hunter, Paul Kinahan, and Robert Miyaoka are with Dept of Rad., U. of Wa, Seattle, WA 98195 USA.
Sergei DolinskySergei Dolinsky is with GE Research, Semiconductors, Niskayuna, NY, 12309, USA.
Paul KinahanWilliam Hunter, Paul Kinahan, and Robert Miyaoka are with Dept of Rad., U. of Wa, Seattle, WA 98195 USA.
Robert MiyaokaWilliam Hunter, Paul Kinahan, and Robert Miyaoka are with Dept of Rad., U. of Wa, Seattle, WA 98195 USA.

Funding

A TOF, DOI, MRI compatible PET detector to support sub-millimeter neuroPET imagingR01EB026964 · NIBIB · UNIVERSITY OF WASHINGTON · PI DOLINSKY, SERGEI, MIYAOKA, ROBERT S · 2018 to 2019
$1.1M
NIBIB NIH HHS R01 EB026964
6 · The paper itself

Abstract

We evaluated the 3D spatial, energy, and timing resolution of the Brain (or Breast)-Initiative Next-Generation (BING) PET detector. The BING detector is an array of 1-mm-thick slats of LYSO scintillator with lapped specular-reflective faces (15-mm by 52-mm) that are stacked together and oriented with their long-narrow edges normal to the imaging field of view. Interaction positions are determined from the signals of silicon-photomultiplier (SiPM) arrays placed on the entrance (top) and exit (bottom) faces. The SiPM arrays are offset to determine the slat of interaction (SOI) without requiring any optical light sharing between slats. Maximum likelihood 2D location within the SOI is determined using the sensor signals. Interaction time is determined with a modified first-optical-photon pickoff method. Performance of the BING detector was measured as a function of position using a sideways coincidence-collimated beam. Slats were accurately identified, with an effective tangential detector resolution of 1 mm. Average resolutions (and ranges) are: 0.96 mm (0.85 mm to 1.11 mm) for lateral (axial) detector resolution, 1.6 mm (1.0 mm to 2.1 mm) for depth resolution, 13.6% (12.7% to 16.0%) for energy resolution, and 317 ps (241 ps to 404 ps) for coincidence timing resolution. Initial spatial and timing resolution results demonstrated that the BING detector can be effective in a small field-of view (e.g., brain or breast) PET system.

Identifiers

PMID36644761
PMCPMC9835997

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.