Evidence map›Paper›PMID 36643278›Full record

ArticleJournal of dental sciences2023

Biomechanical evaluation of bridge span with three implant abutment designs and two connectors for tooth-implant supported prosthesis: A finite element analysis.

Ling-Shiuan Huang, Yen-Chang Huang, Cadmus Yuan, Shinn-Jyh Ding, Min Yan

Open access · goldAbstract read
In one paragraph

Article in Journal of dental sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Ling-Shiuan HuangInstitute of Oral Sciences, Chung Shan Medical University, Taichung, Taiwan.
Yen-Chang HuangInstitute of Oral Sciences, Chung Shan Medical University, Taichung, Taiwan.
Cadmus YuanDepartment of Mechanical and Computer-aided Engineering, Feng Chia University, Taichung, Taiwan.
Shinn-Jyh DingInstitute of Oral Sciences, Chung Shan Medical University, Taichung, Taiwan.
Min YanInstitute of Oral Sciences, Chung Shan Medical University, Taichung, Taiwan.
Chung Shan Medical University · TWChung Shan Medical University Hospital · TWFeng Chia University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background/purpose: Bridge stability under loading was influenced by bridge span with the connector and implant abutment design. Thus, the purpose of this study was to evaluate the effects of rigid and non-rigid connector designs and pontic connections of different abutment systems in the tooth-implant supported prosthesis (TISP) at different span distances on the biomechanical stress distribution of the overall system components. Materials and methods: For comparative analysis, rigid and non-rigid bridge connections were fitted with three implant abutment systems (one-piece, two-piece and three-piece), and five implant-to-natural tooth distance configurations (12 mm, 14 mm, 16 mm, 18 mm, and 20 mm) were provided. Results: The maximum stress between TISP components occurred at the distal side of crown margin of cement1 in rigid connector with one-piece group and the bottom of the crown3 in non-rigid connector with one-piece group, while the other groups were more concentrated at the junction between the mesial side of the implant collar and the abutment. In addition, neither the rigid nor non-rigid connector model showed that stress distribution increased proportionally with the bridge span distance. Conclusion: It was clinically recommended that if the implant with a shorter bridge distance of 12 mm from the natural tooth, the rigid connection of the three-piece abutment can be used as the TISP design. If the bridge distance was 18 mm longer, the non-rigid connection of the three-piece abutment could maintain the physiological movement of the natural tooth and avoid the excessive stress on the bone crest around the implant.

Indexed as

BiomechanicsBridge span distanceFinite element analysisNon-rigid connectorTooth-implant supported prosthesis

Identifiers

PMID36643278
PMCPMC9831793
OpenAlexW4293072333

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.