Clinical outcomes of MANTA vs suture-based vascular closure devices after transcatheter aortic valve replacement: An updated meta-analysis.

Rajkumar Doshi, Rahul Vasudev, Nirmal Guragai, Kunal Nitinkumar Patel, Ashish Kumar, Monil Majmundar, Preet Doshi, Prem Patel, Kalpesh Shah, Melvin Santana and 5 more

Open access · goldAbstract readMeta-Analysis
In one paragraph

Synthesis in Indian heart journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.8field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 6 institutions in 2 countries.

Rajkumar DoshiDepartment of Cardiology, St Joseph University Medical Center, Paterson, NJ, USA. Electronic address: raj20490@gmail.com.
Rahul VasudevDepartment of Cardiology, St Joseph University Medical Center, Paterson, NJ, USA.
Nirmal GuragaiDepartment of Cardiology, St Joseph University Medical Center, Paterson, NJ, USA.
Kunal Nitinkumar PatelDepartment of Internal Medicine, Saint Peter's University Hospital, New Brunswick, NJ, USA.
Ashish KumarDepartment of Internal Medicine Cleveland Clinic Akron General, Akron, OH, USA.
Monil MajmundarDepartment of Cardiology, University of Kansas Medical Center, Kansas City, KS, USA.
Preet DoshiDepartment of Medicine, MS Ramaiah Medical College, Bengaluru, India.
Prem PatelDepartment of Cardiology, St Joseph University Medical Center, Paterson, NJ, USA.
Kalpesh ShahDepartment of Cardiology, St Joseph University Medical Center, Paterson, NJ, USA.
Melvin SantanaDepartment of Cardiology, St Joseph University Medical Center, Paterson, NJ, USA.
Sherif RomanDepartment of Cardiology, St Joseph University Medical Center, Paterson, NJ, USA.
Saraschandra VallabhajosyulaSection of Cardiovascular Medicine, Department of Medicine, Wake Forest University School of Medicine, Winston-Salem, NC, USA.
Hartaj VirkDepartment of Cardiology, St Joseph University Medical Center, Paterson, NJ, USA.
Mahesh BikkinaDepartment of Cardiology, St Joseph University Medical Center, Paterson, NJ, USA.
Fayez ShamoonDepartment of Cardiology, St Joseph University Medical Center, Paterson, NJ, USA.
St. Joseph’s University Medical Center · USCleveland Clinic · USM.S. Ramaiah Medical College · INSaint Peter's University Hospital · USUniversity of Kansas Medical Center · USWake Forest University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveA recently published randomized control trial showed different results with suture-based vascular closure device (VCD) than plug-based VCD in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). The learning curve for MANTA device is steep, while the learning curve for suture based VCD is shallow as the devices are quite different. In this meta-analysis, we have compared suture-based (ProGlide and Prostar XL) vs plug-based VCDs (MANTA).

methodsWe performed a meta-analysis of all published studies (using PubMed/Medline and Cochrane databases) reporting the clinical outcome of plug-based vs suture-based VCDs in transfemoral TAVR patients.

resultsWe included nine studies with a total of 2865 patients (plug-based n = 1631, suture-based n = 1234). There was no significant difference in primary outcome of all bleeding when using plug-based as opposed to suture-based VCDs (RR 1.14 [0.62-2.06] I

conclusionLarge bore arteriotomy closure with plug-based VCD was not superior to suture-based VCDs in this transfemoral TAVR population. There was very frequent use of secondary VCDs in suture-based VCD group which is not practical when using MANTA. Additional high-powered studies are required to determine the safety and efficacy of MANTA device.

Indexed as

Aortic Valve StenosisTranscatheter Aortic Valve ReplacementVascular Closure DevicesAortic ValveFemoral ArteryHemostatic TechniquesHumansSuturesTreatment OutcomeBleedingBlood transfusionDevice failureTranscatheter aortic valve replacementVascular closure deviceVascular complications

Identifiers

PMID36640840
PMCPMC9986740
OpenAlexW4315642987

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.