Evidence map›Paper›PMID 36640199›Full record

ArticleMedical & biological engineering & computing2023

Novel screw fixation placement configuration for the treatment of Pauwels type III femoral neck fractures: a finite element analysis.

Petra Adamović, Janoš Kodvanj, Dejan Blažević, Srećko Sabalić

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Petra AdamovićExperimental Mechanics Laboratory, Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Ivana Lučića 5, 10000, Zagreb, Croatia. petra.adamovic@fsb.hr.ORCID http://orcid.org/0000-0002-6313-2452
Janoš KodvanjExperimental Mechanics Laboratory, Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Ivana Lučića 5, 10000, Zagreb, Croatia.ORCID http://orcid.org/0000-0003-3814-9161
Dejan BlaževićDepartment of Traumatology, Sestre Milosrdnice University Hospital Center, Draškovićeva 19, 10000, Zagreb, Croatia.ORCID http://orcid.org/0000-0003-2908-2508
Srećko SabalićDepartment of Traumatology, Sestre Milosrdnice University Hospital Center, Draškovićeva 19, 10000, Zagreb, Croatia.ORCID http://orcid.org/0000-0003-0070-5206

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Verticality of transcervical hip fractures in young patients is usually connected with typically high-energy fractures which are known as Pauwels type III. Artificial femoral head replacement surgery is mostly not considered for treating femoral neck fractures in such patients. The commonly used devices for the fixation of vertical femoral neck fractures are multiple screws or a sliding hip screw with or without an antirotation screw. Size, location and length of the screws are the most effective parameters in terms of the structural performance of internal fixation implants, but the optimal configuration of the screws is necessary to be investigated to direct the clinical practice. The aim of this study is to compare the biomechanical stability of the standard inverted triangle configuration with the various newly proposed x-crossed screw configurations. FEA simulations carried out in this study demonstrated that using an x-crossed-right assembly in treating Pauwels type III femoral neck fractures satisfies the biomechanical stability in terms of maximum von Mises stresses and maximum femoral head displacement. However, in terms of maximum relative neck fracture displacement, the x-crossed-right assembly would not entirely suffice the desired biomechanical stability. Therefore, using an x-crossed screw assembly in treating femoral neck fractures would provide the needed biomechanical stability.

Indexed as

Bone ScrewsFemoral Neck FracturesBiomechanical PhenomenaFinite Element AnalysisFracture Fixation, InternalHumansBiomechanical stabilityFemoral neck fractureFinite element analysisInverted trianglePauwels type III

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.