ArticlePloS one2023
How much should you worry about contaminant neutrons in spatially fractionated grid radiation therapy?
Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- A Comparative Analysis of Virtual 2D VMAT-Based SFRT and 3D Lattice Radiotherapy: Evaluation of Dosimetric and Therapeutic Outcomes.Journal of biomedical physics & engineering · 2026Article
- Dosimetric characterization for GRID collimator-based spatially fractionated radiation therapy: Dosimetric parameter acquisition and machine interchangeability investigation.Journal of applied clinical medical physics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 7 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Neutron contamination in radiation therapy is of concern in treatment with high-energy photons (> 10 MV). With the development of new radiotherapy modalities such as spatially fractionated grid radiation therapy (SFGRT) or briefly grid radiotherapy, more studies are required to evaluate the risks associated with neutron contamination. In 15 MV SFGRT, high-Z materials such as lead and cerrobend are used as the block on the tray of linear accelerator (linac) which can probably increase the photoneutron production. On the other hand, the high-dose fractions (10-20 Gy) used in SFGRT can induce high neutron contamination. The current study was devoted to addressing these concerns via compression of neutron fluence (Φn) and ambient dose equivalent ([Formula: see text]) at the patient table and inside the maze between SFGRT and conventional fractionated radiation therapy (CFRT). The main components of the 15 MV Siemens Primus equipped with different grids and located inside a typical radiotherapy bunker were simulated by the MCNPX® Monte Carlo code. Evidence showed that the material used for grid construction does not significantly increase neutron contamination inside the maze. However, at the end of the maze, neutron contamination in SFGRT is significantly higher than in CFRT. In this regard, a delay time of 15 minutes after SFGRT is recommended for all radiotherapy staff before entering the maze. It can be also concluded that [Formula: see text] at the patient table is at least 10 times more pronounced than inside the maze. Therefore, the patient is more at risk of neutrons compared to the staff. The [Formula: see text] at the isocenter in SFGRT with grids made of lead and cerrobend was nearly equal to CFRT. Nevertheless, it was dramatically lower than in CFRT by 30% if the brass grid is used. Accordingly, SFGRT with the brass grid is recommended, from radiation protection aspects.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.