Evidence map›Paper›PMID 36636925›Full record

ArticleOrthopaedic surgery2023

Effectiveness and Accuracy of a Patient-Specific Instrumentation System for Total Hip Arthroplasty.

Teng Zhang, Zhao Jia, Wei Han, Junqiang Wang, Jinqi Li, Maoqi Gong, Xieyuan Jiang

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Teng ZhangBeijing Jishuitan Hospital, Trauma Orthopedics, Beijing, China.ORCID https://orcid.org/0000-0001-9195-312X
Zhao JiaBeijing Jishuitan Orthopaedic Robot Engineering Research Center Co., LTD, Beijing, China.
Wei HanBeijing Jishuitan Hospital, Trauma Orthopedics, Beijing, China.
Junqiang WangBeijing Jishuitan Hospital, Trauma Orthopedics, Beijing, China.
Jinqi LiBeijing Jishuitan Orthopaedic Robot Engineering Research Center Co., LTD, Beijing, China.
Maoqi GongBeijing Jishuitan Hospital, Trauma Orthopedics, Beijing, China.
Xieyuan JiangBeijing Jishuitan Hospital, Trauma Orthopedics, Beijing, China.ORCID https://orcid.org/0000-0002-2993-1357
Peking University · CN

Funding

Natural Science Foundation of Beijing Municipality L202028Natural Science Foundation of Beijing Municipality L212009
6 · The paper itself

Abstract

objectiveTraditional total hip arthroplasty (THA) is often performed by visual inspection due to the lack of reliable reference, which results in inappropriate position of prosthesis and poor outcomes. This study attempts to introduce a novel patient-specific instrumentation (PSI) system and assess its effectiveness and accuracy compared with freehand operation and robot system through bone model experiments.

methodsEqually divide 30 sawbone models into the freehand group, PSI group, and robot group. Ten sets of prosthesis parameters were randomly generated as planning, and the three groups underwent simulated THA depending on these parameters. After the placement of the femoral prosthesis, the acetabular anteversion plan was adjusted in the PSI and robot groups so that the combined anteversion was maintained before and after adjustment. After the surgery, the actual prosthesis parameters of all bone models were measured and analyzed statistically.

resultsNo statistically significant difference was found in femoral anteversion error among the three groups (p = 0.951). The errors of acetabular cup anteversion, acetabular cup abduction, and combined anteversion in PSI group were 3.92° (2.94°, 4.62°), 5.65° (4.63°, 6.70°), and 3.93° (2.94°, 4.62°), respectively, which were significantly smaller than those in the freehand group [11.84° (9.92°, 13.87°), 13.54° (9.81°, 15.21°), 16.04° (8.18°, 19.25°), respectively, p < 0.05], but significantly larger than those in the robot group [1.34° (0.98°, 1.70°), 1.80° (1°, 2.02°), 1.34° (0.98°, 1.70°), respectively, p < 0.05].

conclusionCompared with the traditional freehand operation, the patient-specific instrumentation system is feasible in total hip arthroplasty because it improves the accuracy of prosthesis placement. In addition, the rapid measurement of intraoperative femoral prosthesis parameters can help surgeons optimize preoperative planning.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisSurgery, Computer-AssistedAcetabulumHumansProsthesis DesignCombined AnteversionPatient-Specific InstrumentationRoboticsSurgical NavigationTotal Hip Arthroplasty

Identifiers

PMID36636925
PMCPMC9977596
OpenAlexW4315865398

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.