Optimal threshold of a control parameter for tomotherapy respiratory tracking: A phantom study.

Keisuke Sano, Masayuki Fujiwara, Wataru Okada, Masao Tanooka, Haruyuki Takaki, Mayuri Shibata, Kenji Nakamura, Yusuke Sakai, Hitomi Suzuki, Kanae Takahashi and 2 more

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Keisuke SanoDepartment of Radiology, Hyogo Medical University, Nishinomiya, Hyogo, Japan.
Masayuki FujiwaraDepartment of Radiology, Hyogo Medical University, Nishinomiya, Hyogo, Japan.
Wataru OkadaDepartment of Radiology, Hyogo Medical University, Nishinomiya, Hyogo, Japan.
Masao TanookaDepartment of Radiology, Hyogo Medical University, Nishinomiya, Hyogo, Japan.
Haruyuki TakakiDepartment of Radiology, Hyogo Medical University, Nishinomiya, Hyogo, Japan.
Mayuri ShibataDepartment of Radiotherapy, Takarazuka City Hospital, Takarazuka, Hyogo, Japan.
Kenji NakamuraDepartment of Radiotherapy, Takarazuka City Hospital, Takarazuka, Hyogo, Japan.
Yusuke SakaiDepartment of Radiotherapy, Takarazuka City Hospital, Takarazuka, Hyogo, Japan.
Hitomi SuzukiDepartment of Radiology, Hyogo Medical University, Nishinomiya, Hyogo, Japan.
Kanae TakahashiDepartment of Biostatistics, Hyogo Medical University, Nishinomiya, Hyogo, Japan.
Masahiro TanakaDepartment of Radiotherapy, Takarazuka City Hospital, Takarazuka, Hyogo, Japan.
Koichiro YamakadoDepartment of Radiology, Hyogo Medical University, Nishinomiya, Hyogo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRadixact Synchrony PURPOSE: This study aims to determine the optimal threshold of the potential difference of Radixact Synchrony

methodsThe relationship among the dosimetric accuracy, motion tracking accuracy, and control parameter was evaluated using a moving platform, a phantom with a basic respiratory model (the fourth power of a sinusoidal wave), and several irregular respiratory model waveforms. The dosimetric accuracy was evaluated by gamma analysis (3%, 1 mm, 10% dose threshold). The tracking accuracy was measured by the distance error of the difference between the tracked and driven positions of the phantom. The largest potential difference for 95% of treatment time was evaluated, and its correlation with the gamma-pass ratio and distance error was investigated. The optimal threshold of the potential difference was determined by receiver operating characteristic (ROC) analysis.

resultsA linear correlation was identified between the potential difference and the gamma-pass ratio (R = -0.704). A linear correlation was also identified between the potential difference and distance error (R = 0.827). However, as the potential difference increased, it tended to underestimate the distance error. The ROC analysis revealed that the appropriate cutoff value of the potential difference was 3.05 mm.

conclusionThe irradiation accuracy with motion tracking by Radixact Synchrony

Indexed as

NeoplasmsRadiotherapy, Intensity-ModulatedHumansMotionPhantoms, ImagingRadiometrydosimetric accuracyrespiratory trackingtomotherapy

Identifiers

PMID36635847
PMCPMC10161055

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.