Evidence map›Paper›PMID 36635446›Full record

ReviewOrthopadie (Heidelberg, Germany)2023

[Standard and special liner in primary hip arthroplasty : Current study and survey results from the German Arthroplasty Registry (EPRD)].

Paula Krull, Arnd Steinbrück, Alexander W Grimberg, Oliver Melsheimer, Michael M Morlock, Carsten Perka

Abstract readEnglish AbstractReview
PubMed Publisher
In one paragraph

Review in Orthopadie (Heidelberg, Germany), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Paula KrullEndoprothesenregister Deutschland (EPRD gGmbH), Str. des 17. Juni 106-108, 10623, Berlin, Deutschland. krull@eprd.de.
Arnd SteinbrückEndoprothesenregister Deutschland (EPRD gGmbH), Str. des 17. Juni 106-108, 10623, Berlin, Deutschland.
Alexander W GrimbergEndoprothesenregister Deutschland (EPRD gGmbH), Str. des 17. Juni 106-108, 10623, Berlin, Deutschland.
Oliver MelsheimerEndoprothesenregister Deutschland (EPRD gGmbH), Str. des 17. Juni 106-108, 10623, Berlin, Deutschland.
Michael M MorlockTechnische Universität Hamburg (TUHH), Am Schwarzenberg-Campus 1, 21073, Hamburg, Deutschland.
Carsten PerkaCentrum für Muskuloskeletale Chirurgie (CMSC), Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Deutschland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInstability constitutes the main reason for revision hip arthroplasties. Modified polyethylene liners are designed to improve the stability of a hip replacement. In July 2022 The Bone & Joint Journal published a study with data of the German Arthroplasty Registry (EPRD). The study investigated mechanical failure of standard and modified liner designs in primary, cementless total hip arthroplasty. Following the study, the EPRD conducted a survey of German clinics to research the utilization of lipped liners in primary total hip replacement.

methodsThe liner study included 151,096 primary, elective, cementless total hip arthroplasties. Data from November 2012 to November 2020 were obtained from the EPRD. Standard polyethylene liners were compared with lipped, angulated, offset and angulated/offset inlays. Cumulative incidences for endpoint revision due to mechanical complication were calculated with a competing risk analysis. The influence of other variables was investigated with a multivariate Cox regression. In the following online survey, 237 out of 789 hospitals completed a form. RESULTS AND

conclusionIn our analysis, only offset liners were, compared to standard liners, associated with a reduced risk of mechanical failure in a short to medium follow up. However, the resultant joint reaction force is increased with offset liners due to the lateralization of the hip center of rotation. Thus, the long-term performance of offset liners needs to be observed. Our survey indicated that lipped liners were implanted more often if the posterior approach was used. Moreover, lipped liners were mostly positioned with the elevated rim in the biomechanically less optimal posterior-superior quadrant. To improve stability it is suggested to position the elevated rim in the posterior-inferior quadrant.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisPolyethyleneProsthesis DesignRegistriesReoperationPolyethyleneHospitalsLinerRisk assessmentSurveyTotal hip replacement

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.