In one paragraph

Article in Pediatric radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed, 1 pooled it
11.7field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 1 synthesis or guideline pooled it, 51 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Observational
  5. [Pediatric sarcomas].Radiologie (Heidelberg, Germany) · 2026
    Review
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Observational
  12. Article
  13. [Magnetic resonance imaging of the pediatric chest].Radiologie (Heidelberg, Germany) · 2025
    Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Ilias TsiflikasDepartment of Diagnostic and Interventional Radiology, University Hospital, Eberhard Karls University Tuebingen, Tuebingen, Germany.
Greta ThaterDepartment of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
Isabelle AyxDepartment of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
Jakob WeissDepartment of Radiology, Freiburg University Hospital, Freiburg, Germany.
Juergen SchaeferDepartment of Diagnostic and Interventional Radiology, University Hospital, Eberhard Karls University Tuebingen, Tuebingen, Germany.
Thomas SteinDepartment of Radiology, Freiburg University Hospital, Freiburg, Germany.
Stefan O SchoenbergDepartment of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
Meike WeisDepartment of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany. meike.weis@medma.uni-heidelberg.de.ORCID 0000-0002-8085-6612
Heidelberg University · DEUniversity Medical Center Freiburg · DEUniversity of Tübingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWith the clinical release of a photon counting detector-based computed tomography (CT) system, the potential benefits of this new technology need to be evaluated clinically. Literature concerning this new generation of detector is sparse, especially in the field of pediatric radiology. Therefore, this study outlines our initial experience with ultra-low dose chest CT imaging on the new photon counting CT system. MATERIALS AND

methodsA pediatric phantom (1-year old, CIRS ATOM phantom, model 704 [CIRS-computerized imaging reference system, Norfolk, VA]) was scanned at different dose levels and different image quality levels to define a protocol for clinical examinations. Next, 20 consecutive pediatric non-contrast ultra-low dose chest CT examinations were evaluated for radiation dose and diagnostic image quality using a 4-point Likert-scale-1 = excellent, 4 = bad image quality-by two radiologists in a consensus reading. This retrospective analysis was approved by the local research ethics committee.

resultsChest CT examinations performed at ultra-low radiation dose (effective dose 0.19 ± 0.07 mSv; size-specific dose estimate 0.45 ± 0.14 mGy) in pediatric patients ages (2.6 ± 1.8 years) show good to excellent image quality for lung structures (1.4 ± 0.4) and moderate image quality for soft tissue structures (2.8 ± 0.2).

conclusionPediatric ultra-low dose chest CT examinations are feasible with the new generation photon counting detector-based CT system. The benefits of this technology must be evaluated for pediatric patients from the outset.

Indexed as

LungTomography, X-Ray ComputedChildHumansInfantPhantoms, ImagingPhotonsRadiation DosageRetrospective StudiesALARAChestChildrenComputed tomographyImage gentlyLow dosePhantomPhoton countingRadiationUltra-low dose

Identifiers

PMID36635378
PMCPMC10212801
OpenAlexW4315783631

What OpenQuestion holds

Textmetadata
LicenceCC BY