ArticleJournal of the American Society for Mass Spectrometry2023
Developments in Trapped Ion Mobility Mass Spectrometry to Probe the Early Stages of Peptide Aggregation.
Article in Journal of the American Society for Mass Spectrometry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 18 citations in OpenAlex.
- Hyphenated Mass Spectrometry-Based Strategies for Characterizing Oligomers of α‑Synuclein in Parkinson's Disease.ACS central science · 2026Article
- Article
- Hyphenation of Trapped Ion Mobility to Two-Dimensional Mass Spectrometry for Protein Analysis in Complex Biomixtures.Journal of the American Society for Mass Spectrometry · 2025Article
- Amyloid Light Chain Proteins in Cardiovascular Disease: Pathogenesis and Emerging Therapies for Cardiac Amyloidosis.Pharmaceutical research · 2025Review
- IR Action Spectroscopy of Mass- and Mobility-Selected α-Synuclein Segments: Structure Identification in Early-Stage Oligomers via the Amide A Region.The journal of physical chemistry. A · 2025Article
- High-Throughput Single-Particle Characterization of Aggregation Pathways and the Effects of Inhibitors for Large (Megadalton) Protein Oligomers.Analytical chemistry · 2024Article
- Risk assessment of oligomers and potentially harmful chemical compounds from food packaging simulated using an in vitro digestion model.EFSA journal. European Food Safety Authority · 2024Article
- Unraveling the Structure and Dynamics of Ac-PHF6-NHACS chemical neuroscience · 2024Article
- Probing High-Order Transient Oligomers Using Ion Mobility Mass Spectrometry Coupled with Infrared Action Spectroscopy.Analytical chemistry · 2024Article
- Exploring the Aggregation Propensity of PHF6 Peptide Segments of the Tau Protein Using Ion Mobility Mass Spectrometry Techniques.Analytical chemistry · 2024Article
- Unraveling Posttranslational Modification Complexity: Advances in Quantitative Histone Proteoform Mass Spectrometry.Mass spectrometry reviewsReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Ion mobility mass spectrometry (IM-MS) has proven to be an excellent method to characterize the structure of amyloidogenic protein and peptide aggregates, which are formed in coincidence with the development of neurodegenerative diseases. However, it remains a challenge to obtain detailed structural information on all conformational intermediates, originating from the early onset of those pathologies, due to their complex and heterogeneous environment. One way to enhance the insights and the identification of these early stage oligomers is by employing high resolution ion mobility mass spectrometry experiments. This would allow us to enhance the mobility separation and MS characterization. Trapped ion mobility spectrometry (TIMS) is an ion mobility technique known for its inherently high resolution and has successfully been applied to the analysis of protein conformations among others. To obtain conformational information on fragile peptide aggregates, the instrumental parameters of the TIMS-Quadrupole-Time-of-Flight mass spectrometer (TIMS-qToF-MS) have to be optimized to allow the study of intact aggregates and ensure their transmission toward the detector. Here, we investigate the suitability and application of TIMS to probe the aggregation process, targeting the well-characterized M307-N319 peptide segment of the TDP-43 protein, which is involved in the development of amyotrophic lateral sclerosis. By studying the influence of key parameters over the full mass spectrometer, such as source temperature, applied voltages or RFs among others, we demonstrate that by using an optimized instrumental method TIMS can be used to probe peptide aggregation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.