Evidence map›Paper›PMID 36633691›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2023

Facet joint violation after open and percutaneous posterior instrumentation: a comparative study.

Marian Mitterer, Reinhold Ortmaier, Teresa Wiesner, Wolfgang Hitzl, Michael Mayer

Abstract read
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Marian MittererDepartment of Orthopaedics and Traumatology, Paracelsus Medical University Salzburg, Müllner Hauptstraße 48, 5020, Salzburg, Austria. marian.mitterer@me.com.ORCID 0000-0002-9277-6791
Reinhold OrtmaierDepartment of Orthopedic Surgery, Vinzenzgruppe Center of Orthopedic Excellence, Ordensklinikum Barmherzige Schwestern Linz, Teaching Hospital of the Paracelsus Medical University, Salzburg, Austria.
Teresa WiesnerDepartment of Orthopaedics and Traumatology, Paracelsus Medical University Salzburg, Müllner Hauptstraße 48, 5020, Salzburg, Austria.
Wolfgang HitzlDepartment of Biostatistics, Paracelsus Medical University, Salzburg, Austria.
Michael MayerDepartment of Orthopaedics and Traumatology, Paracelsus Medical University Salzburg, Müllner Hauptstraße 48, 5020, Salzburg, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePosterior instrumentation is the state-of-the-art surgical treatment for fractures of the thoracic and lumbar spine. Options for pedicle screw placement comprise open or minimally invasive techniques. Open instrumentation causes large approach related muscle detachment, which minimally invasive techniques aim to reduce. However, concerns of accurate pedicle screw placement are still a matter of debate. Beside neurological complications due to pedicle screw malplacement, also affection of the facet joints and thus motion dependent pain is known as a complication. The aim of this study was to assess accuracy of pedicle screw placement concerning facet joint violation (FJV) after open- and minimally invasive posterior instrumentation.

methodsA retrospective data analysis of postoperative computer tomographic scans of 219 patients (1124 pedicle screws) was conducted. A total of 116 patients underwent open screw insertion (634 screws) and 103 patients underwent minimally invasive, percutaneous screw insertion (490 screws).

resultsIn the lumbar spine (segments L3, L4, L5), there were significantly more and higher grade (open = 0.55 vs. percutaneous = 1.2; p = 0.001) FJV's after percutaneously compared to openly inserted screws. In the thoracic spine, no significant difference concerning rate and grade of FJV was found (p > 0.56).

conclusionFJV is more likely to occur in percutaneously placed pedicle screws. Additionally, higher grade FJV's occur after percutaneous instrumentation. However, in the thoracic spine we didn't find a significant difference between open and percutaneous technique. Our results suggest a precise consideration concerning surgical technique according to the fractured vertebrae in the light of the individual anatomic structures in the preop CT.

Indexed as

Pedicle ScrewsSpinal FracturesSpinal FusionZygapophyseal JointHumansLumbar VertebraeRetrospective StudiesFacet jointFacet joint violationPedicle screwPosterior instrumentationSpine surgery