ReviewArteriosclerosis, thrombosis, and vascular biology2023
Tissue Engineering of Vascular Grafts: A Case Report From Bench to Bedside and Back.
Review in Arteriosclerosis, thrombosis, and vascular biology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- Perivascular administration of metformin through 3D minichannels improved adventitia ingrowth and endothelialization for electrospinning vascular grafts.Bioactive materials · 2026Article
- Preconditioned endothelialized grafts reduce stenosis and improve vascular remodeling in a rat pulmonary artery model.Acta biomaterialia · 2026Article
- Review
- Chronic kidney disease and stromal cell-derived factor 1α peptide-functionalization impact on polycarbonate-bisurea based in situ tissue-engineered vascular graft dynamics.Scientific reports · 2026Article
- Evolutions in Cardiovascular Implants-A Review of Past, Present, and Future.Micromachines · 2026Review
- Shear Preconditioning Restores Endothelial Function of HLHS Patient-Derived iPSC-ECs for Successful Conduit Implantation.Arteriosclerosis, thrombosis, and vascular biology · 2026Article
- Reinforced biotubes as readily available and regenerative vascular grafts.Nature communications · 2026Article
- Optimized biomechanical design of a tissue engineered pulsatile Fontan conduit.NPJ Regenerative medicine · 2026Article
- Don't judge an implant by its cover: how the foreign body response and fibrotic capsule might be harnessed for good.npj biomedical innovations · 2026Review
- Biodegradable Synthetic Graft with Sustained Hydrogen Sulfide Release Promotes Endothelial Cell Growth.Macromolecular bioscience · 2025Article
- Nanomedicine-based strategies for the treatment of vein graft disease.Nature reviews. Cardiology · 2025Review
- Vascular endothelial cells derived from transgene-free pig induced pluripotent stem cells for vascular tissue engineering.Acta biomaterialia · 2025Article
- Biocomposite Scaffolds for Tissue Engineering: Materials, Fabrication Techniques and Future Directions.Materials (Basel, Switzerland) · 2024Review
- Off-the-Shelf Synthetic Biodegradable Grafts Transform In Situ into a Living Arteriovenous Fistula in a Large Animal Model.Advanced healthcare materials · 2024Article
- Fabrication of a Triple-Layer Bionic Vascular Scaffold via Hybrid Electrospinning.Journal of functional biomaterials · 2024Article
- Comparison of the Patency and Regenerative Potential of Biodegradable Vascular Prostheses of Different Polymer Compositions in an Ovine Model.International journal of molecular sciences · 2023Article
- A narrative review of vascular conduits for coronary artery bypass grafting.Cell transplantationReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
For over 25 years, our group has used regenerative medicine strategies to develop improved biomaterials for use in congenital heart surgery. Among other applications, we developed a tissue-engineered vascular graft (TEVG) by seeding tubular biodegradable polymeric scaffolds with autologous bone marrow-derived mononuclear cells. Results of our first-in-human study demonstrated feasibility as the TEVG transformed into a living vascular graft having an ability to grow, making it the first engineered graft with growth potential. Yet, outcomes of this first Food and Drug Administration-approved clinical trial evaluating safety revealed a prohibitively high incidence of early TEVG stenosis, preventing the widespread use of this promising technology. Mechanistic studies in mouse models provided important insight into the development of stenosis and enabled advanced computational models. Computational simulations suggested both a novel inflammation-driven, mechano-mediated process of in vivo TEVG development and an unexpected natural history, including spontaneous reversal of the stenosis. Based on these in vivo and in silico discoveries, we have been able to rationally design strategies for inhibiting TEVG stenosis that have been validated in preclinical large animal studies and translated to the clinic via a new Food and Drug Administration-approved clinical trial. This progress would not have been possible without the multidisciplinary approach, ranging from small to large animal models and computational simulations. This same process is expected to lead to further advances in scaffold design, and thus next generation TEVGs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.