Evidence map›Paper›PMID 36631843›Full record

ArticleJournal of orthopaedic surgery and research2023

Silica coated high performance oxide ceramics promote greater ossification than titanium implants: an in vivo study.

Filippo Migliorini, Hanno Schenker, Marcel Betsch, Nicola Maffulli, Markus Tingart, Frank Hildebrand, Sophie Lecouturier, Björn Rath, Jörg Eschweiler

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
0.5field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Subsidence of the Corail stem in total hip arthroplasty: no influence of bony contact.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 6 institutions in 5 countries.

Filippo Migliorini *Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany. Migliorini.md@gmail.com.ORCID http://orcid.org/0000-0001-7220-1221
Hanno Schenker *Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
Marcel BetschDepartment of Orthopedics, University Hospital of Erlangen, 91054, Erlangen, Germany.
Nicola MaffulliDepartment of Medicine, Surgery and Dentistry, University of Salerno, 84081, Baronissi, SA, Italy. n.maffulli@qmul.ac.uk.
Markus TingartOrtho-Centrum Aachen (OCA), Aachen, Germany.
Frank HildebrandDepartment of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
Sophie LecouturierDepartment of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
Björn RathDepartment of Orthopaedic Surgery, Klinikum Wels-Grieskirchen, 4600, Wels, Austria.
Jörg EschweilerDepartment of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
RWTH Aachen University · DEAachener Centrum für Technologietransfer in der Ophthalmologie · DEKlinikum Wels-Grieskirchen · ATOrthopaedic Trauma Association · USUniversitätsklinikum Erlangen · DEUniversity of Salerno · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis in vitro study investigated the osseointegration and implant integration of high performance oxide ceramics (HPOC) compared to titanium implants in rabbits.

methodsHistomorphometry was conducted around the distal, proximal, medial, and lateral aspects of the HPOC to quantify the amount of mature and immature ossification within the bone interface. Histomorphometry was conducted by a trained musculoskeletal pathologist. The region of interest (ROI) represented the percentage of surrounding area of the implant. The percentage of ROI covered by osteoid implant contact (OIC) and mature bone implant contact (BIC) were assessed. The surrounding presence of bone resorption, necrosis, and/or inflammation were quantitatively investigated.

resultsAll 34 rabbits survived the 6- and 12-week experimental period. All HPOC implants remained in situ. The mean weight difference from baseline was + 647.7 mg (P < 0.0001). The overall OIC of the ceramic group was greater at 6 weeks compared to the titanium implants (P = 0.003). The other endpoints of interest were similar between the two implants at all follow-up points. No difference was found in BIC at 6- and 12-weeks follow-up. No bone necrosis, resorption, or inflammation were observed.

conclusionHPOC implants demonstrated a greater osteoid implant contact at 6 weeks compared to the titanium implants, with no difference found at 12 weeks. The percentage of bone implant contact of HPOC implants was similar to that promoted by titanium implants.

Indexed as

OsteogenesisTitaniumAnimalsCeramicsCoated Materials, BiocompatibleImplants, ExperimentalOsseointegrationOxidesRabbitsSilicon DioxideSurface PropertiesCoated Materials, BiocompatibleOxidesSilicon DioxideTitaniumHigh performance oxide ceramicsImplantologyOssification

Identifiers

PMID36631843
PMCPMC9832611
OpenAlexW4315649465

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked