Evidence map›Paper›PMID 36629961›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2023

Maximizing QRS duration reduction in contemporary cardiac resynchronization therapy is feasible and shorter QRS duration is associated with better clinical outcome.

Rasmus Borgquist, Sofia Marinko, Pyotr G Platonov, Lingwei Wang, Uzma Chaudhry, Johan Brandt, David Mörtsell

Abstract read
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rasmus BorgquistArrhythmia section, Skane University Hospital, Entrégatan 7, 222 42, Lund, Sweden. rasmus.borgquist@med.lu.se.ORCID http://orcid.org/0000-0002-1365-6637
Sofia MarinkoCardiology section, Department of clinical sciences, Lund University, Lund, Sweden.
Pyotr G PlatonovCardiology section, Department of clinical sciences, Lund University, Lund, Sweden.
Lingwei WangCardiology section, Department of clinical sciences, Lund University, Lund, Sweden.
Uzma ChaudhryCardiology section, Department of clinical sciences, Lund University, Lund, Sweden.
Johan BrandtCardiology section, Department of clinical sciences, Lund University, Lund, Sweden.
David MörtsellCardiology section, Department of clinical sciences, Lund University, Lund, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWe aimed to evaluate if optimization by maximizing QRS duration (QRSd) reduction is feasible in an all-comer cardiac resynchronization therapy (CRT) population, and if reduced, QRSd is associated with a better clinical outcome.

methodsPatients with LBBB receiving CRT implants during the period 2015-2020 were retrospectively evaluated. Implants from 2015-2017 were designated as controls. Starting from 2018, an active 12-lead electrogram-based optimization of QRSd reduction was implemented (intervention group). QRSd reduction was evaluated in a structured way at various device AV and VV settings, aiming to maximize the reduction. The primary endpoint was a composite of heart failure hospitalization or death from any cause.

resultsA total of 254 patients were followed for up to 6 years (median 2.9 [1.8-4.1]), during which 82 patients (32%) reached the primary endpoint; 53 deaths (21%) and 58 (23%) heart failure hospitalizations. Median QRS duration pre-implant was 162 ms [150-174] and post-implant 146ms [132-160]. Mean reduction in QRS duration was progressively larger for each year during the intervention period, ranging from - 9.5ms in the control group to - 24 in the year 2020 (p = 0.005). QRS reduction > 14 ms (median value) was associated with a lower risk of death or heart failure hospitalization (adjusted HR 0.54 [0.29-0.98] (p = 0.04).

conclusionsImplementing a general strategy of CRT device optimization by aiming for shorter QRS duration is feasible in a structured clinical setting and results in larger reductions in QRS duration post-implant. In patients with a larger QRS reduction, compared to those with a smaller QRS reduction, there is an association with a better clinical outcome.

Indexed as

Bundle-Branch BlockCardiac Resynchronization TherapyElectrocardiographyHeart FailureAgedFeasibility StudiesFemaleHumansMaleMiddle AgedRetrospective StudiesTreatment OutcomeCRTDevice optimizationHeart failureHeart failure hospitalizationMortality

Identifiers

PMID36629961
PMCPMC10570164

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.