ArticleLung India : official organ of Indian Chest Society
Therapeutic efficacy of oscillating positive expiratory pressure therapy in stable chronic obstructive pulmonary disease.
Article in Lung India : official organ of Indian Chest Society. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.
- Oscillating Positive Expiratory Pressure (OPEP) Therapy in Bronchiectasis and Chronic Obstructive Pulmonary Disease (COPD): A Narrative Review of Clinical Studies.Pulmonary therapy · 2026Pooled it
- A Prospective, Multicenter Study Investigating the Effectiveness of an Oscillating Positive Expiratory Pressure (OPEP) Device in COPD Patients in Québec, Canada.Canadian respiratory journal · 2026Article
- Impact of AerobikaFrontiers in medicine · 2023Article
- Efficacy of oscillating PEP therapy in COPD: Is the significance clinically relevant?Lung India : official organ of Indian Chest SocietyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Chronic obstructive pulmonary disease (COPD) is characterized by persistent airflow limitation that is usually progressive and associated with an enhanced chronic inflammatory response in the airway and the lung to noxious particles or gases. Sputum production is a cardinal feature in COPD. Airway clearance techniques have been the mainstay of management. Oscillating positive expiratory pressure (OPEP) devices are handheld devices that provide a combination of positive expiratory pressure (PEP) with high frequency oscillations which involve exhaling against a resistance that is fluctuating. It encourages airflow within secretions, whereas oscillations induce vibrations within airway wall to displace secretions into airway lumen and help in expectoration. Methods: A randomized control trial was conducted at the department of pulmonary medicine, Government Medical College & Hospital, Chandigarh, in which 50 patients with stable COPD were enrolled for one- and- half years. After taking proper history, they were subjected to spirometry, six- minute walk test, and were asked to fill the St. George's Respiratory Questionnaire (SGRQ) and COPD Assessment Test (CAT). These patients were randomized into group A (intervention group) and group B (control group), where group A was prescribed Aerobika OPEP device for daily use for a period of three months. After three months of use of device, the patients were again subjected to assessment parameters and inquired about any exacerbation within the three- month period. Results: At the end of three months were compared with baseline results. The median change in FEV1, FVC, 6MWD from baseline in group A was significantly more as compared to group B (FEV1: P < 0.001; FVC: P < 0.001; 6MWD: P = 0.08), whereas SGRQ score showed a significant improvement in both the intervention and control groups (P < 0.001) and CAT score showed significant improvement in comparison to the control group (P < 0.001). The median change in 6MWD and CAT from baseline in group A was significantly more as compared to group B (SGRQ: P < 0.001; CAT: P < 0.001), whereas it was not significant in case of SGRQ (P = 0.233). There was no significant difference in the incidence of exacerbation in the two groups (P = 0.19). The device did not help in controlling the rate of exacerbation in the present study at three months. Conclusion: Stable COPD patients who were given OPEP therapy as an adjunct to the standard drug therapy showed improvement in the spirometry parameters, exercise capacity and symptom burden in comparison to the drug only group.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.