Evidence map›Paper›PMID 36629070›Full record

ArticleInvestigative and clinical urology2023

Laparoscopic renal surgery using multi degree-of-freedom articulating laparoscopic instruments in a porcine model.

Jong Keun Kim, Bosik Kang, Yu Seon Kim, Yujin Yun, Myoung Jin Jang, Donghwan Bae, Dalsan You

Open access · diamondAbstract read
In one paragraph

Article in Investigative and clinical urology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 15 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. The continuing legacy ofInvestigative and clinical urology · 2024
    Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Jong Keun KimDepartment of Urology, Hallym University Dongtan Sacred Heart Hospital, Hwaseong, Korea.ORCID 0000-0001-6507-2628
Bosik KangDepartment of Urology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.ORCID 0000-0001-8497-4133
Yu Seon KimDepartment of Urology, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.ORCID 0000-0002-0390-5062
Yujin YunRobotic Surgery Center, Asan Medical Center, Seoul, Korea.ORCID 0000-0003-2185-8463
Myoung Jin JangAsan Institute for Life Sciences, Asan Medical Center, Seoul, Korea.ORCID 0000-0001-8123-5001
Donghwan BaeLIVSMED, Seongnam, Korea.ORCID 0000-0001-9562-6062
Dalsan YouDepartment of Urology, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. dalsanyou@amc.seoul.kr.ORCID 0000-0001-8152-847X
Ulsan College · KRAsan Medical Center · KRHallym University Dongtan Sacred Heart Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe evaluated the performance of a new multi-degree-of-freedom articulating laparoscopic instrument, ArtiSential, and compared it with that of a straight-shaped instrument and the da Vinci surgical system, in renal surgery using porcine model. MATERIALS AND

methodsNine female Yorkshire pigs were equally divided into three groups. The three groups were compared at each surgical step in terms of objective and subjective parameters.

resultsThe median operative times for renal pedicle clamping and ureter dissection were significantly shorter in ArtiSential group than robotic group (1.3 min vs. 4.7 min, p=0.002; 8.1 min vs. 11.1 min, p=0.015). The median operative time for bladder repair was significantly longer in ArtiSential group than robotic and straight-shaped groups (17.9 min vs. 5.5 min, p=0.002; 17.9 min vs. 9.3 min, p=0.026). There were no significant differences among groups in terms of blood loss or intraoperative complications. ArtiSential device was less useable for renorrhaphy (p=0.009) and bladder repair (p=0.002) compared to the robotic system. ArtiSential group was less accurate than robotic group in terms of tumor resection, renorrhaphy, and bladder repair. During ureter dissection, bladder cuff excision, and bladder repair, the surgeon experienced greater wrist discomfort but lesser back discomfort in ArtiSential group than robotic group.

conclusionsFor most steps, ArtiSential performed as well as robotic and straight-shaped instruments. The development of specialized surgical techniques for ArtiSential will maximize the advantages of these instruments.

Indexed as

KidneyLaparoscopyAnimalsFemaleModels, AnimalOperative TimeRoboticsSwineTreatment OutcomeUreterUrologic Surgical ProceduresJointsKidneyLaparoscopyRobotics

Identifiers

PMID36629070
PMCPMC9834568
OpenAlexW4312415307

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.