Evidence map›Paper›PMID 36627551›Full record

ArticleBMC anesthesiology2023

Disposable laryngoscope intubation to reduce equipment failure in an emergency out of OR setting - a quality control case study.

Colby G Simmons, Tobias Eckle, Dustin Rogers, Jason D Williams, Jason C Brainard

Open access · goldAbstract read
In one paragraph

Article in BMC anesthesiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 99% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

Colby G SimmonsDepartment of Anesthesiology, University of Colorado School of Medicine, 12401 E. 17th Ave Leprino Bldg #734Anschutz Medical Campus, Aurora, CO, USA. Colby.Simmons@cuanschutz.edu.
Tobias EckleDepartment of Anesthesiology, University of Colorado School of Medicine, 12401 E. 17th Ave Leprino Bldg #734Anschutz Medical Campus, Aurora, CO, USA.
Dustin RogersDepartment of Biostatistics and Informatics, University of Colorado School of Public Health, Fitzsimons Building, 4th Floor 13001 E. 17th Place Mail Stop B119 Anschutz Medical Campus, Aurora, CO, USA.
Jason D WilliamsSaint Alphonsus Regional Medical Center, 1055 North Curtis Rd, Boise, ID, USA.
Jason C BrainardDepartment of Anesthesiology, University of Colorado School of Medicine, 12401 E. 17th Ave Leprino Bldg #734Anschutz Medical Campus, Aurora, CO, USA.
University of Colorado Denver · USColorado School of Public Health · USSaint Alphonsus Regional Medical Center · USUniversity of Colorado Anschutz Medical Campus · US

Funding

Anesthesiology Mentored Research TrainingT32GM135169 · NIGMS · UNIVERSITY OF COLORADO DENVER · PI Susan L Ingram, Vesna Jevtovic-Todorovic · 2021 to 2026
$1.0M
Targeting the endothelial clock to treat perioperative myocardial ischemiaR56HL156955 · NHLBI · UNIVERSITY OF COLORADO DENVER · PI DE LA GARZA ECKLE, TOBIAS · 2022 to 2022
$383k
NHLBI NIH HHS R56 HL156955
6 · The paper itself

Abstract

backgroundReusable laryngoscopes have been reported to be superior to disposable laryngoscopes with plastic blades during emergent intubations. Surprisingly, at our institution a quality reporting system revealed a high number of equipment failures with reusable laryngoscopes in an emergency out-of-OR (operating room) setting. As recent studies indicated an improved quality of disposable laryngoscopes, we hypothesized that a thoroughly evaluated disposable laryngoscope would result in less equipment failure in an emergency out-of-OR setting.

methodsTo perform a more standardized and time efficient analysis, four distinct disposable laryngoscope blade/handle configurations were trialed during standard intubations (n = 4 × 30) in the OR by experienced anesthesia providers who completed a 6-question, Likert-scale/open-ended survey for product evaluation. The 'best' disposable blade was implemented in an emergency out-of-OR setting and equipment failure rates were monitored over a 3-year period.

resultsDifferent disposable laryngoscopes were equal regarding sturdiness, illumination and airway visualization. The laryngoscope with the highest overall score was significantly higher scored than the laryngoscope with the lowest overall score. All disposable laryngoscopes were more cost effective than the reusable ones, and the top scored laryngoscope demonstrated the highest 5-year cost-saving ($210 K). Implementation of the top scored disposable laryngoscope into an emergency out-of-OR setting reduced the equipment failure incidence from high 20s to 0.

conclusionDisposable laryngoscopes are cost effective and superior to reusable laryngoscopes in an emergency out-of-OR setting. We demonstrate that the implementation of a disposable laryngoscope in the emergency out-of-OR setting resulted in a near elimination of equipment related quality submissions which ultimately enhances patient safety.

Indexed as

LaryngoscopesDisposable EquipmentEquipment DesignEquipment FailureHumansIntubation, IntratrachealSurveys and QuestionnairesAirway managementCost-effectivenessEnvironmental sustainabilityPatient safetyQuality ImprovementValue

Identifiers

PMID36627551
PMCPMC9830876
OpenAlexW4315486305

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.