The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review.

Krisdiyanto, Raja Ariffin Bin Raja Ghazilla, M Azuddin, Muhammad Khairi Faiz Bin Ahmad Hairuddin, Muhammad Akhsin Muflikhun, Nurvita Risdiana, Eki Afifuddin

Open access · goldAbstract readReview
In one paragraph

Review in Medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Observational
  2. Gravimetric compounding workflow technology insights for pharmacists and pharmacy technicians.American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists · 2025
    Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 3 countries.

KrisdiyantoCPDM, Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.ORCID 0000-0002-6587-7343
Raja Ariffin Bin Raja GhazillaCPDM, Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.
M AzuddinCPDM, Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.
Muhammad Khairi Faiz Bin Ahmad HairuddinCPDM, Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.
Muhammad Akhsin MuflikhunMechanical and Industrial Engineering Department, Faculty of Engineering, Universitas Gadjah Mada, Yogyakarta, Indonesia.
Nurvita RisdianaDepartment of Mental Health Nursing, School of Nursing, Universitas Muhammadiyah Yogyakarta, Yogyakarta, Indonesia.
Eki AfifuddinMechanical and Industrial Engineering Department, Faculty of Engineering, Universitas Gadjah Mada, Yogyakarta, Indonesia.
University of Malaya · MYMuhammadiyah University of Yogyakarta · IDUniversitas Gadjah Mada · ID

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A syringe is used to inject fluid or medicine into the patient's soft tissue. The main components of the syringe were the needle, barrel, and plunger. The use of syringes in the medical world is relatively high, and especially since the COVID-19 pandemic, the use of hypodermic syringes increased sharply due to vaccination. The syringe used must be effective and of good quality, so the International Organization for Standardization (ISO) has published test procedures and minimum specifications for hypodermic syringes. The performance of the syringe can be observed from the dead space, force piston operation, water and air leakage, and fitting position of the plunger in the barrel. This review shows that most researchers use the weighing method to measure the dead space, although some use other methods. The researchers found that most of the products met the minimum specifications of the ISO, and that the dimensions and shape of the syringe affected the dead space. Researchers have not examined other performance measures recommended by the ISO. Researchers have focused more on force injection than force piston operation, leakage after injection or back spray than air and water leakage, and reduction the friction of the plunger without considering the fitting position of the plunger in the barrel.

Indexed as

COVID-19SyringesHumansPandemicsReference StandardsWaterWater

Identifiers

PMID36626504
PMCPMC9750608
OpenAlexW4315436403

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.